Seismic evaluation of a four-story apartment building in Matina, Davao City using non-linear dynamic analysis in accordance with ASCE 41-17

The increasing frequency and intensity of seismic activity in the Philippines posed significant challenges to ensuring urban buildings' safety and structural integrity. This study focused on evaluating the seismic performance of a mid-rise apartment building through nonlinear dynamic analysis, following the guidelines set by the American Society of Civil Engineers (ASCE) 41-17 and the National Structural Code of the Philippines (NSCP) 2015, utilizing ETABS software. Earthquake records from the Pacific Earthquake Engineering Research Center (PEER) database, specifically those exhibiting seismic behavior similar to Davao's, were used to simulate ground motions and determine maximum base shear and displacement. The initial analysis results failed to meet the Life Safety performance level criteria, prompting retrofitting measures. After retrofitting, the base shear increased by 15 times along the x-axis and three times along the y-axis. Additionally, displacement decreased by 92.96% in the x-axis and 81.55% in the y-axis, indicating enhanced structural stiffness and resistance to seismic forces. These results confirmed a substantial improvement in the building's resilience to local earthquake impacts.

Authors

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2026-02-16
DOI
https://doi.org/10.1051/e3sconf/202669404001/pdf
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Seismic evaluation of a four-story apartment building in Matina, Davao City using non-linear dynamic analysis in accordance with ASCE 41-17

Danielyn F. Plazos, Yestin John Epa, Dinah Ross Degorio, Elan Bollifer
Springer Link (Chiba Institute of Technology)
Seismic Performance and Analysis
article

Seismic evaluation of a four-story apartment building in Matina, Davao City using non-linear dynamic analysis in accordance with ASCE 41-17

Danielyn F. Plazos, Yestin John Epa, Dinah Ross Degorio, Elan Bollifer
article en

Abstract

The increasing frequency and intensity of seismic activity in the Philippines posed significant challenges to ensuring urban buildings' safety and structural integrity. This study focused on evaluating the seismic performance of a mid-rise apartment building through nonlinear dynamic analysis, following the guidelines set by the American Society of Civil Engineers (ASCE) 41-17 and the National Structural Code of the Philippines (NSCP) 2015, utilizing ETABS software. Earthquake records from the Pacific Earthquake Engineering Research Center (PEER) database, specifically those exhibiting seismic behavior similar to Davao's, were used to simulate ground motions and determine maximum base shear and displacement. The initial analysis results failed to meet the Life Safety performance level criteria, prompting retrofitting measures. After retrofitting, the base shear increased by 15 times along the x-axis and three times along the y-axis. Additionally, displacement decreased by 92.96% in the x-axis and 81.55% in the y-axis, indicating enhanced structural stiffness and resistance to seismic forces. These results confirmed a substantial improvement in the building's resilience to local earthquake impacts.

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 54%
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.