Performance verification of blood vessel detection system using near-infrared light

BackgroundNear-infrared (NIR) imaging technology has been increasingly applied in clinical and biomedical engineering fields for subcutaneous vein detection and vascular guidance. However, most existing systems still face limitations such as inconsistent visualization under various skin tones and difficulties in achieving real-time projection alignment.ObjectiveThe objective of this study is to develop a near-infrared (NIR)-based vascular detection system and to evaluate its performance.MethodsThe developed system provides intuitive visualization by projecting vascular images in real time onto the same skin region. Performance validation was conducted using a vascular model and the abdominal vessels of rabbits.ResultsIn the vascular model experiment, the localization accuracy was 98.9%, and in the rabbit experiment, the detection success rate for vessels with a diameter of ≥1 mm was 100%.ConclusionsThe proposed method was confirmed to reduce the time required for acquiring anatomical knowledge and to minimize complications by preventing incorrect venipuncture.

Authors

Institutions

Publication Details

Journal
Technology and Health Care
Published
2026-02-16
DOI
https://doi.org/10.1177/09287329251414328
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance verification of blood vessel detection system using near-infrared light

Jieun Park, Junghun Kim
Technology and Health Care
Optical Imaging and Spectroscopy Techniques
article

Performance verification of blood vessel detection system using near-infrared light

Jieun Park, Junghun Kim
article en

Abstract

BackgroundNear-infrared (NIR) imaging technology has been increasingly applied in clinical and biomedical engineering fields for subcutaneous vein detection and vascular guidance. However, most existing systems still face limitations such as inconsistent visualization under various skin tones and difficulties in achieving real-time projection alignment.ObjectiveThe objective of this study is to develop a near-infrared (NIR)-based vascular detection system and to evaluate its performance.MethodsThe developed system provides intuitive visualization by projecting vascular images in real time onto the same skin region. Performance validation was conducted using a vascular model and the abdominal vessels of rabbits.ResultsIn the vascular model experiment, the localization accuracy was 98.9%, and in the rabbit experiment, the detection success rate for vessels with a diameter of ≥1 mm was 100%.ConclusionsThe proposed method was confirmed to reduce the time required for acquiring anatomical knowledge and to minimize complications by preventing incorrect venipuncture.

Technology and Health Care
Daegu Catholic University (KR)
Openalex Percentile: Top 53%
Optical Imaging and Spectroscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.