Optimization of the sensitivity of a Fabry–Pérot pressure sensor based on a PDMS microlens at the end of a graded-index multimode fiber

In this work, we present the design and optimization of a Fabry–Pérot interferometric (FPI) pressure sensor integrated at the tip of a 62.5/125 µm graded-index multimode fiber (GI-MMF). The fiber is chemically modified using a 20% hydrofluoric acid (HF) solution, enabling the formation of concave micro-cavities. Polydimethylsiloxane (PDMS) is then introduced into these micro-cavities to form microlenses with varying geometries. Pressure and temperature sensitivities are obtained through finite element method (FEM) simulations based on the actual micro-cavity geometries and microlens thicknesses characterized experimentally. The simulated sensor response shows, for the identified optimal configuration, a pressure sensitivity of 92 pm/kPa over a range of 10–154 kPa, as well as a temperature sensitivity of 363 pm/°C over a range of 25°C–61°C. A full experimental validation of these performances is planned in future work.

Authors

Institutions

Publication Details

Journal
Journal of the Optical Society of America B
Published
2026-02-17
DOI
https://doi.org/10.1364/josab.581777
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of the sensitivity of a Fabry–Pérot pressure sensor based on a PDMS microlens at the end of a graded-index multimode fiber

Sebti Mohamed, Assia Guessoum, Laouamri Hind, Abdelhak Guermat et al.
Journal of the Optical Society of America B
Advanced Fiber Optic Sensors
article

Optimization of the sensitivity of a Fabry–Pérot pressure sensor based on a PDMS microlens at the end of a graded-index multimode fiber

Sebti Mohamed, Assia Guessoum, Laouamri Hind, Abdelhak Guermat, MOHAMED LOGHRAB, bouchaour mounir, Nacer Eddine Demagh, ghoumazi mehdi, hicheur salim, adouane azzedine
article en

Abstract

In this work, we present the design and optimization of a Fabry–Pérot interferometric (FPI) pressure sensor integrated at the tip of a 62.5/125 µm graded-index multimode fiber (GI-MMF). The fiber is chemically modified using a 20% hydrofluoric acid (HF) solution, enabling the formation of concave micro-cavities. Polydimethylsiloxane (PDMS) is then introduced into these micro-cavities to form microlenses with varying geometries. Pressure and temperature sensitivities are obtained through finite element method (FEM) simulations based on the actual micro-cavity geometries and microlens thicknesses characterized experimentally. The simulated sensor response shows, for the identified optimal configuration, a pressure sensitivity of 92 pm/kPa over a range of 10–154 kPa, as well as a temperature sensitivity of 363 pm/°C over a range of 25°C–61°C. A full experimental validation of these performances is planned in future work.

Journal of the Optical Society of America BVol. 43(4)
University of Science and Technology (YE), Centre for Development of Advanced Computing (IN), University of Sciences and Technology Houari Boumediene (DZ), University Ferhat Abbas of Setif (DZ), Yung Shin Pharmaceutical Industrial (Taiwan) (TW)
Affordable and clean energy
Openalex Percentile: Top 53%
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.