Study on modular smoke extraction with solid screen in urban road tunnel fires

A series of numerical simulations were conducted to evaluate and optimize a modular smoke extraction system integrated with smoke screens for urban road tunnel fires. The study aimed to identify key design parameters and propose optimal strategies for tunnel-wide smoke management. The results show that smoke screen height is a critical factor, with a threshold of 1.5 m (25% of tunnel height) significantly enhancing extraction efficiency and reducing high-temperature zones, while vent-screen distance has minimal impact. Dividing the tunnel into five modular zones achieves the optimal balance between hazard control and system cost. Furthermore, an unbalanced airflow distribution strategy-allocating 35% of the total exhaust volume (180 m³/s) to proximate vents and 15% to distal vents-proves most effective in preventing plug-holing phenomenon and maximizing CO extraction efficiency. These findings provide specific design thresholds and actionable strategies for the optimization of transverse smoke extraction systems in urban road tunnels.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2026-02-17
DOI
https://doi.org/10.1371/journal.pone.0342557
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on modular smoke extraction with solid screen in urban road tunnel fires

Yushi Lu, Xiaotao Zhang, Kaihua Lu
PLoS ONE
Fire dynamics and safety research
article

Study on modular smoke extraction with solid screen in urban road tunnel fires

Yushi Lu, Xiaotao Zhang, Kaihua Lu
article en

Abstract

A series of numerical simulations were conducted to evaluate and optimize a modular smoke extraction system integrated with smoke screens for urban road tunnel fires. The study aimed to identify key design parameters and propose optimal strategies for tunnel-wide smoke management. The results show that smoke screen height is a critical factor, with a threshold of 1.5 m (25% of tunnel height) significantly enhancing extraction efficiency and reducing high-temperature zones, while vent-screen distance has minimal impact. Dividing the tunnel into five modular zones achieves the optimal balance between hazard control and system cost. Furthermore, an unbalanced airflow distribution strategy-allocating 35% of the total exhaust volume (180 m³/s) to proximate vents and 15% to distal vents-proves most effective in preventing plug-holing phenomenon and maximizing CO extraction efficiency. These findings provide specific design thresholds and actionable strategies for the optimization of transverse smoke extraction systems in urban road tunnels.

PLoS ONEVol. 21(2)
Xidian University (CN), China University of Geosciences (CN)
Sustainable cities and communities
Openalex Percentile: Top 62%
Fire dynamics and safety research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.