Study on modular smoke extraction with solid screen in urban road tunnel fires
A series of numerical simulations were conducted to evaluate and optimize a modular smoke extraction system integrated with smoke screens for urban road tunnel fires. The study aimed to identify key design parameters and propose optimal strategies for tunnel-wide smoke management. The results show that smoke screen height is a critical factor, with a threshold of 1.5 m (25% of tunnel height) significantly enhancing extraction efficiency and reducing high-temperature zones, while vent-screen distance has minimal impact. Dividing the tunnel into five modular zones achieves the optimal balance between hazard control and system cost. Furthermore, an unbalanced airflow distribution strategy-allocating 35% of the total exhaust volume (180 m³/s) to proximate vents and 15% to distal vents-proves most effective in preventing plug-holing phenomenon and maximizing CO extraction efficiency. These findings provide specific design thresholds and actionable strategies for the optimization of transverse smoke extraction systems in urban road tunnels.
Authors
- Yushi Lu
- Xiaotao Zhang (ORCID: https://orcid.org/0009-0004-3157-9032)
- Kaihua Lu
Institutions
- Xidian University (CN)
- China University of Geosciences (CN)
Publication Details
- Journal
- PLoS ONE
- Published
- 2026-02-17
- DOI
- https://doi.org/10.1371/journal.pone.0342557
- Primary Topic
- Fire dynamics and safety research
- Type
- article
- Field-Weighted Citation Impact
- 0.00