A Simple Method to Minimize Humidity Measurement Error in Psychrometers

This work demonstrates that simple calibration procedures can reduce the errors in determining relative humidity with a psychrometer by up to 75 times. The psychrometer uses two temperature transducers to measure relative humidity. The calibration consists of comparing both transducers before assembling the psychrometer. A psychrometer assembly is presented, built from readily available parts, which provides temperature data for comparison with a theoretical model. The results are compared against a reference psychrometer to assess errors with and without calibration. A twenty-two-fold decrease in error was observed for a relative humidity of 62%.

Authors

Institutions

Publication Details

Journal
J — Multidisciplinary Scientific Journal
Published
2026-02-17
DOI
https://doi.org/10.3390/j9010007
Primary Topic
Intravenous Infusion Technology and Safety
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Simple Method to Minimize Humidity Measurement Error in Psychrometers

Edson Massayuki Kakuno, Fabrício Ferrari, John W. B. de Araújo, Daniel F. C. Ferrando et al.
J — Multidisciplinary Scientific Journal
Intravenous Infusion Technology and Safety
article

A Simple Method to Minimize Humidity Measurement Error in Psychrometers

Edson Massayuki Kakuno, Fabrício Ferrari, John W. B. de Araújo, Daniel F. C. Ferrando, Pedro A. B. Kuroda
article en

Abstract

This work demonstrates that simple calibration procedures can reduce the errors in determining relative humidity with a psychrometer by up to 75 times. The psychrometer uses two temperature transducers to measure relative humidity. The calibration consists of comparing both transducers before assembling the psychrometer. A psychrometer assembly is presented, built from readily available parts, which provides temperature data for comparison with a theoretical model. The results are compared against a reference psychrometer to assess errors with and without calibration. A twenty-two-fold decrease in error was observed for a relative humidity of 62%.

J — Multidisciplinary Scientific JournalVol. 9(1)
Universidade Federal do Rio Grande (BR), Universidade Federal da Integração Latino-Americana (BR), Universidade Federal do Paraná (BR), Universidade Federal do Pampa (BR), University of Rio Grande and Rio Grande Community College (US)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico, Universidade Federal do Pampa
Openalex Percentile: Top 54%
Intravenous Infusion Technology and Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Simple Method to Minimize Humidity Measurement Error in Psychrometers — Edson Massayuki Kakuno, Fabrício Ferrari, et al. · J — Multidisciplinary Scientific Journal (2026) | TGRS Research Map | TGRS