Photon-counting CT versus Energy-integrating Detector CT in Imaging Lung Cancer

Background Although energy-integrating detector (EID) CT remains the standard in diagnosing and monitoring lung cancer, it has limitations compared with photon-counting CT (PCCT). However, the role of low-dose PCCT in evaluating lung cancer remains unexplored. Purpose To compare the diagnostic quality of chest CT images from PCCT with a low radiation dose and a low injection rate, volume, and concentration of contrast agent (hereafter, a "quadruple-low protocol") with that of EID CT in patients with lung cancer. Materials and Methods This retrospective study included patients with lung cancer undergoing PCCT or EID CT between July 2024 and September 2024. Patients underwent PCCT with the low radiation dose plus reduced contrast agent protocol (quadruple-low protocol: 2.0 mL/sec injection rate, 1.0 mL/kg of 320 mg of iodine per milliliter) and EID CT with a conventional protocol. Two radiologists independently evaluated the subjective image quality and lesion imaging features. Lesion and parenchymal metrics (attenuation, signal-to-noise ratio [SNR], and contrast-to-noise ratio [CNR]) were also assessed. Data were compared using the Student <i>t</i> test, Mann-Whitney <i>U</i> test, or multivariable regression. Sensitivity analysis was performed using propensity score matching. Results Among 425 participants (mean age, 61 years ± 9.5 [SD]; 273 men), PCCT reduced radiation dose by 55% (mean effective dose, 3.49 mSv ± 0.91 vs 7.82 mSv ± 2.15; <i>P</i> < .001) while lowering contrast agent injection rate, volume, and concentration by 33% (<i>P</i> < .001), 22% (<i>P</i> < .001), and 9% (<i>P</i> < .001), respectively. PCCT reduced the incidence of contrast-induced nephropathy (CIN) compared with EID CT (0% [0 of 120] vs 7.9% [24 of 305], <i>P</i> = .02). PCCT also exhibited higher objective SNR and CNR in lung lesions and parenchyma, with superior subjective image quality scores and increased diagnostic confidence for imaging features (all adjusted <i>P</i> < .001). Results remained consistent in sensitivity analysis. Conclusion Compared with EID CT, PCCT with a quadruple-low protocol reduced the incidence of CIN and enhanced image quality and diagnostic confidence in imaging features in patients with lung cancer. © RSNA, 2026 <i>Supplemental material is available for this article</i>.

Authors

Institutions

Publication Details

Journal
Radiology
Published
2026-02-01
DOI
https://doi.org/10.1148/radiol.251126
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Photon-counting CT versus Energy-integrating Detector CT in Imaging Lung Cancer

Zhigang Zhou, Junqiang Dong, X. B. Li, Kehui Nie et al.
Radiology
Advanced X-ray and CT Imaging
article

Photon-counting CT versus Energy-integrating Detector CT in Imaging Lung Cancer

Zhigang Zhou, Junqiang Dong, X. B. Li, Kehui Nie, Songwei Yue, Xiaofei Yang, Ke Qi, Yonggao Zhang, Mingxin Li, Jianbo Gao, Qianqian Zhao
article en

Abstract

Background Although energy-integrating detector (EID) CT remains the standard in diagnosing and monitoring lung cancer, it has limitations compared with photon-counting CT (PCCT). However, the role of low-dose PCCT in evaluating lung cancer remains unexplored. Purpose To compare the diagnostic quality of chest CT images from PCCT with a low radiation dose and a low injection rate, volume, and concentration of contrast agent (hereafter, a "quadruple-low protocol") with that of EID CT in patients with lung cancer. Materials and Methods This retrospective study included patients with lung cancer undergoing PCCT or EID CT between July 2024 and September 2024. Patients underwent PCCT with the low radiation dose plus reduced contrast agent protocol (quadruple-low protocol: 2.0 mL/sec injection rate, 1.0 mL/kg of 320 mg of iodine per milliliter) and EID CT with a conventional protocol. Two radiologists independently evaluated the subjective image quality and lesion imaging features. Lesion and parenchymal metrics (attenuation, signal-to-noise ratio [SNR], and contrast-to-noise ratio [CNR]) were also assessed. Data were compared using the Student <i>t</i> test, Mann-Whitney <i>U</i> test, or multivariable regression. Sensitivity analysis was performed using propensity score matching. Results Among 425 participants (mean age, 61 years ± 9.5 [SD]; 273 men), PCCT reduced radiation dose by 55% (mean effective dose, 3.49 mSv ± 0.91 vs 7.82 mSv ± 2.15; <i>P</i> < .001) while lowering contrast agent injection rate, volume, and concentration by 33% (<i>P</i> < .001), 22% (<i>P</i> < .001), and 9% (<i>P</i> < .001), respectively. PCCT reduced the incidence of contrast-induced nephropathy (CIN) compared with EID CT (0% [0 of 120] vs 7.9% [24 of 305], <i>P</i> = .02). PCCT also exhibited higher objective SNR and CNR in lung lesions and parenchyma, with superior subjective image quality scores and increased diagnostic confidence for imaging features (all adjusted <i>P</i> < .001). Results remained consistent in sensitivity analysis. Conclusion Compared with EID CT, PCCT with a quadruple-low protocol reduced the incidence of CIN and enhanced image quality and diagnostic confidence in imaging features in patients with lung cancer. © RSNA, 2026 <i>Supplemental material is available for this article</i>.

RadiologyVol. 318(2)
International Medical Corps (US), Henan University of Engineering (CN), Siemens Healthcare (United States) (US), First Affiliated Hospital of Zhengzhou University (CN)
Good health and well-being
Openalex Percentile: Top 54%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.