Performance Improvement of the Acrylic Acid–Polyvinyl Alcohol Gel Dosimeter with an Organic Additive for Radiation Oncology Applications

This study reports the first preparation and characterization of an acrylic acid-glucose-polyvinyl alcohol (ACAGLPVA) polymer gel dosimeter incorporating glucose as an organic additive for radiation oncology applications. Five formulations with glucose concentrations of 0, 10, 20, 25, and 30 wt% were irradiated using a 6-MV photon beam at doses of 0-60 Gy, and the transverse relaxation rate (R<sub>2</sub>) was measured by nuclear magnetic resonance (NMR) relaxometry. The optimal formulation (25 wt% glucose) demonstrated an excellent linear dose response between 0 and 30 Gy (R<sup>2</sup> = 0.9979) with a sensitivity of 0.177 s<sup>-1</sup> Gy<sup>-1</sup>, followed by a non-linear response at 30-60 Gy. The dosimeter exhibited dose rate independence (200-600 cGy/min), energy independence (6-15 MV), temperature independence (5-35 °C), and post-irradiation stability for at least 7 days. These characteristics demonstrate the potential of ACAGLPVA gel dosimeters for accurate three-dimensional dose verification in modern radiotherapy applications.

Authors

Institutions

Publication Details

Journal
Gels
Published
2026-02-17
DOI
https://doi.org/10.3390/gels12020176
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Improvement of the Acrylic Acid–Polyvinyl Alcohol Gel Dosimeter with an Organic Additive for Radiation Oncology Applications

Belal Moftah, Khalid A. Rabaeh, Abdullah S. Bani Issa, Akram A. Moussa et al.
Gels
Advanced Radiotherapy Techniques
article

Performance Improvement of the Acrylic Acid–Polyvinyl Alcohol Gel Dosimeter with an Organic Additive for Radiation Oncology Applications

Belal Moftah, Khalid A. Rabaeh, Abdullah S. Bani Issa, Akram A. Moussa, Md A. Al Kafi
article en

Abstract

This study reports the first preparation and characterization of an acrylic acid-glucose-polyvinyl alcohol (ACAGLPVA) polymer gel dosimeter incorporating glucose as an organic additive for radiation oncology applications. Five formulations with glucose concentrations of 0, 10, 20, 25, and 30 wt% were irradiated using a 6-MV photon beam at doses of 0-60 Gy, and the transverse relaxation rate (R<sub>2</sub>) was measured by nuclear magnetic resonance (NMR) relaxometry. The optimal formulation (25 wt% glucose) demonstrated an excellent linear dose response between 0 and 30 Gy (R<sup>2</sup> = 0.9979) with a sensitivity of 0.177 s<sup>-1</sup> Gy<sup>-1</sup>, followed by a non-linear response at 30-60 Gy. The dosimeter exhibited dose rate independence (200-600 cGy/min), energy independence (6-15 MV), temperature independence (5-35 °C), and post-irradiation stability for at least 7 days. These characteristics demonstrate the potential of ACAGLPVA gel dosimeters for accurate three-dimensional dose verification in modern radiotherapy applications.

GelsVol. 12(2)
Hashemite University (JO), King Faisal Specialist Hospital & Research Centre (SA), McGill University (CA), Yarmouk University (JO)
King Faisal Specialist Hospital and Research Centre
Affordable and clean energy
Openalex Percentile: Top 48%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Performance Improvement of the Acrylic Acid–Polyvinyl Alcohol Gel Dosimeter with an Organic Additive for Radiation Oncology Applications — Belal Moftah, Khalid A. Rabaeh, et al. · Gels (2026) | TGRS Research Map | TGRS