A Nano-Sized Poly(aniline-co-thiophene) Based Solid-Contact Screen-Printed Electrode for Batch and Continuous Potentiometric Determination of Iodide

Two approaches are described for construction of a screen-printed planar electrode (SPE) for potentiometric determination of iodide ion. The first, involves preparation and application of iron(II) bathophenanthroline tetraiodoplumbate complex ([Fe(bphen)<sub>3</sub>][PbI<sub>4</sub>]), as a sensitive and selective electroactive sensing material in a potentiometric electrode for iodide determination. The second is the use of a nano-sized poly(aniline-co-thiophene) (PANI-co-PT) as a solid-contact material in a planar miniaturized configuration. The SPE displays a Nernstian response for iodide ion with a calibration slope of -58.81 ± 0.69 mV/decade (R<sup>2</sup> = 0.9998) over a wide concentration range (9.17 × 10<sup>-7</sup>-6.94 × 10<sup>-3</sup> mol/L), low detection limit (6.09 × 10<sup>-7</sup> mol/L), rapid response time (5.0 ± 1.0 s) and long-life span (75 ± 3.0 d). The use of PANI-co-PT solid-contact layer significantly improves the ion-to-electron transduction, eliminates the formation of undesired thin water layer between the sensing membrane and the conducting substrate, prevents membrane delamination, enhances potential stability with a significantly reduced potential drift (8.32 ± 0.12 µV/min) and displays high redox capacitance (2.560 ± 0.040 mF). Water contact angle measurements confirm the increased hydrophobicity of the modified membrane electrode (from 44 ± 0.8° to 93 ± 1.4°) and demonstrate the membrane ability to repel moisture and further stabilize the sensor response. The proposed sensor is successfully integrated into a flow injection analysis (FIA) system to enable real-time and continuous iodide monitoring with high precision, high sample throughput and applicability for quality control of pharmaceuticals and environmental monitoring.

Authors

Institutions

Publication Details

Journal
Polymers
Published
2026-02-16
DOI
https://doi.org/10.3390/polym18040492
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Nano-Sized Poly(aniline-co-thiophene) Based Solid-Contact Screen-Printed Electrode for Batch and Continuous Potentiometric Determination of Iodide

Saad S. M. Hassan, Mahmoud Abdelwahab Fathy
Polymers
Analytical Chemistry and Sensors
article

A Nano-Sized Poly(aniline-co-thiophene) Based Solid-Contact Screen-Printed Electrode for Batch and Continuous Potentiometric Determination of Iodide

Saad S. M. Hassan, Mahmoud Abdelwahab Fathy
article en

Abstract

Two approaches are described for construction of a screen-printed planar electrode (SPE) for potentiometric determination of iodide ion. The first, involves preparation and application of iron(II) bathophenanthroline tetraiodoplumbate complex ([Fe(bphen)<sub>3</sub>][PbI<sub>4</sub>]), as a sensitive and selective electroactive sensing material in a potentiometric electrode for iodide determination. The second is the use of a nano-sized poly(aniline-co-thiophene) (PANI-co-PT) as a solid-contact material in a planar miniaturized configuration. The SPE displays a Nernstian response for iodide ion with a calibration slope of -58.81 ± 0.69 mV/decade (R<sup>2</sup> = 0.9998) over a wide concentration range (9.17 × 10<sup>-7</sup>-6.94 × 10<sup>-3</sup> mol/L), low detection limit (6.09 × 10<sup>-7</sup> mol/L), rapid response time (5.0 ± 1.0 s) and long-life span (75 ± 3.0 d). The use of PANI-co-PT solid-contact layer significantly improves the ion-to-electron transduction, eliminates the formation of undesired thin water layer between the sensing membrane and the conducting substrate, prevents membrane delamination, enhances potential stability with a significantly reduced potential drift (8.32 ± 0.12 µV/min) and displays high redox capacitance (2.560 ± 0.040 mF). Water contact angle measurements confirm the increased hydrophobicity of the modified membrane electrode (from 44 ± 0.8° to 93 ± 1.4°) and demonstrate the membrane ability to repel moisture and further stabilize the sensor response. The proposed sensor is successfully integrated into a flow injection analysis (FIA) system to enable real-time and continuous iodide monitoring with high precision, high sample throughput and applicability for quality control of pharmaceuticals and environmental monitoring.

PolymersVol. 18(4)
Ain Shams University (EG), KTH Royal Institute of Technology (SE)
Ain Shams University
Openalex Percentile: Top 56%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Nano-Sized Poly(aniline-co-thiophene) Based Solid-Contact Screen-Printed Electrode for Batch and Continuous Potentiometric Determination of Iodide — Saad S. M. Hassan, Mahmoud Abdelwahab Fathy · Polymers (2026) | TGRS Research Map | TGRS