The LANCET robotic system improves radiographic alignment and prosthesis positioning in TKA: a multicenter, prospective controlled clinical trial

• LANCET robotics assisted TKA achieves better lower limb mechanical alignment • LANCET robotics assisted TKA achieves higher prosthesis placement compliance compared to conventional manual TKA • LANCET robot assisted knee arthroplasty has more blood loss but little change in hemoglobin concentration • LANCET robot-assisted approach shows comparable clinical outcomes (range of motion, functional scores, pain relief) to conventional surgery We introduced a cost-effective semi-automatic total knee arthroplasty (TKA) robotic system-LANCET RobPath and validate its accuracy and effectiveness through a prospective and multicenter trial. A multicenter prospective controlled single-blind clinical trial was conducted by five joint centers. Patients who underwent TKA were admitted and divided into two groups: robot-assisted group (RA group) and conventional manual group (CM group). Patients’ baseline characteristics, clinical subjective assessment indices, radiographic findings, hemoglobin (Hb) level changes, and operative duration were recorded and analyzed. No adverse events related to machine malfunctions occurred. The mean HKA angles of the two groups were (178.5° ± 2.9°) and (177.3° ± 3.7°), respectively (P=0.014). The HKA offset in the RA group was (2.5° ± 2.1°), while (3.6° ± 2.8°) in the CM group (P=0.006). The compliance rates of the planned prostheses were 86.96% and 73.02%, respectively. Compared with the CM group, the RA group extended the surgical time (149.8 ± 46.0 min vs 97.5 ± 32.3 min, P=0.020). At the end of 3-month follow-up period, there was no significant difference between RA and CM groups when assessed by range of motion, Knee Society Score, Visual Analog Scale. The LANCET robot-assisted knee replacement surgery system has good safety, precise surgical planning and osteotomy, and can obtain better lower limb alignment. This robotic system has the potential to be widely applied in clinical practice.

Authors

Institutions

Publication Details

Journal
Advanced Orthopaedics
Published
2026-02-01
DOI
https://doi.org/10.1016/j.advop.2026.02.001
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The LANCET robotic system improves radiographic alignment and prosthesis positioning in TKA: a multicenter, prospective controlled clinical trial

Miaofeng Zhang, Zhihong Xu, Dongyang Chen, Zheng Liu et al.
Advanced Orthopaedics
Total Knee Arthroplasty Outcomes
article

The LANCET robotic system improves radiographic alignment and prosthesis positioning in TKA: a multicenter, prospective controlled clinical trial

Miaofeng Zhang, Zhihong Xu, Dongyang Chen, Zheng Liu, Weijun Wang, Lidong Wu, Jing Han, Jin Dai, Lan Li, Huanyu Zhang, Qing Jiang, Yunfeng Yao, Jianghui Qin, Chenxi Xue, Xiaofeng Zhang, Xinhua Li, Qing Chang, Kai Song, Jun Lu
article en

Abstract

• LANCET robotics assisted TKA achieves better lower limb mechanical alignment • LANCET robotics assisted TKA achieves higher prosthesis placement compliance compared to conventional manual TKA • LANCET robot assisted knee arthroplasty has more blood loss but little change in hemoglobin concentration • LANCET robot-assisted approach shows comparable clinical outcomes (range of motion, functional scores, pain relief) to conventional surgery We introduced a cost-effective semi-automatic total knee arthroplasty (TKA) robotic system-LANCET RobPath and validate its accuracy and effectiveness through a prospective and multicenter trial. A multicenter prospective controlled single-blind clinical trial was conducted by five joint centers. Patients who underwent TKA were admitted and divided into two groups: robot-assisted group (RA group) and conventional manual group (CM group). Patients’ baseline characteristics, clinical subjective assessment indices, radiographic findings, hemoglobin (Hb) level changes, and operative duration were recorded and analyzed. No adverse events related to machine malfunctions occurred. The mean HKA angles of the two groups were (178.5° ± 2.9°) and (177.3° ± 3.7°), respectively (P=0.014). The HKA offset in the RA group was (2.5° ± 2.1°), while (3.6° ± 2.8°) in the CM group (P=0.006). The compliance rates of the planned prostheses were 86.96% and 73.02%, respectively. Compared with the CM group, the RA group extended the surgical time (149.8 ± 46.0 min vs 97.5 ± 32.3 min, P=0.020). At the end of 3-month follow-up period, there was no significant difference between RA and CM groups when assessed by range of motion, Knee Society Score, Visual Analog Scale. The LANCET robot-assisted knee replacement surgery system has good safety, precise surgical planning and osteotomy, and can obtain better lower limb alignment. This robotic system has the potential to be widely applied in clinical practice.

Advanced Orthopaedics
Anhui Medical University (CN), National Clinical Research Center for Digestive Diseases (CN), Zhongda Hospital Southeast University (CN), Nanjing Drum Tower Hospital (CN), Second Affiliated Hospital of Anhui Medical University (CN), Second Affiliated Hospital of Zhejiang University (CN)
Openalex Percentile: Top 54%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.