Bio-Compatibility Analysis of Newly Developed Plug and Cuff Electrodes for Future Neuronal Interface Applications

The NerveRepack project is a European initiative that aims to develop biomimetic exoskeletons/exoprostheses for amputated or paralyzed leg patients that will receive and transmit signals to enable movements and sensations for the patient. To implement the project, it is fundamental to develop implantable neuronal electrodes that will allow bidirectional signaling between the sensors placed on the exoskeletons/exoprostheses and the nervous system. In this direction, two electrodes, plug and cuff, have been designed as integral parts of the final implantable device. The electrodes should comply with strict regulations to ensure their safe implantation in patients. The purpose of this study was to support the compliance of the implant platforms of certain key components with the ISO and ASTM standards that would be required for clinical applications. We have used an indirect method to assess the biocompatibility of the developed electrodes against neuronal cells, fibroblasts, and keratinocytes. Also, we assessed hemocompatibility, i.e., the potential of implantable electrodes to induce hemolysis or complement activation. Finally, the mutagenic/genotoxic potential was tested against the internationally recommended CHO cells. Both representative plug and cuff electrode components were found non-cytotoxic, non-mutagenic, and unable to induce hemolysis. Therefore, from the point of early evaluation of in vitro material and process biocompatibility, the selected implant platforms for the electrodes could be implanted in preclinical models to delineate their potential in vivo applications as neuronal interface with the biomimetic exoskeleton/exoprostheses.

Authors

Institutions

Publication Details

Journal
Biomimetics
Published
2026-02-16
DOI
https://doi.org/10.3390/biomimetics11020147
Primary Topic
Neuroscience and Neural Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bio-Compatibility Analysis of Newly Developed Plug and Cuff Electrodes for Future Neuronal Interface Applications

Eleni Zingkou, David Dragomir, Marian Ion, Gerd Siekmeyer et al.
Biomimetics
Neuroscience and Neural Engineering
article

Bio-Compatibility Analysis of Newly Developed Plug and Cuff Electrodes for Future Neuronal Interface Applications

Eleni Zingkou, David Dragomir, Marian Ion, Gerd Siekmeyer, Georgios Pampalakis, Georgia Sotiropoulou, Carmen Moldovan, Octavian Ionescu, Patryk Śniarowski, Nafsika Rossopoulou, Asimina Kolianou, T. Katsila, Karolina Gzyra-Jagieła, Longina Madej-Kiełbik, Eduard Franti, Aikaterini Skiada, Patrick Grotemeyer, Lydia Galouni
article en

Abstract

The NerveRepack project is a European initiative that aims to develop biomimetic exoskeletons/exoprostheses for amputated or paralyzed leg patients that will receive and transmit signals to enable movements and sensations for the patient. To implement the project, it is fundamental to develop implantable neuronal electrodes that will allow bidirectional signaling between the sensors placed on the exoskeletons/exoprostheses and the nervous system. In this direction, two electrodes, plug and cuff, have been designed as integral parts of the final implantable device. The electrodes should comply with strict regulations to ensure their safe implantation in patients. The purpose of this study was to support the compliance of the implant platforms of certain key components with the ISO and ASTM standards that would be required for clinical applications. We have used an indirect method to assess the biocompatibility of the developed electrodes against neuronal cells, fibroblasts, and keratinocytes. Also, we assessed hemocompatibility, i.e., the potential of implantable electrodes to induce hemolysis or complement activation. Finally, the mutagenic/genotoxic potential was tested against the internationally recommended CHO cells. Both representative plug and cuff electrode components were found non-cytotoxic, non-mutagenic, and unable to induce hemolysis. Therefore, from the point of early evaluation of in vitro material and process biocompatibility, the selected implant platforms for the electrodes could be implanted in preclinical models to delineate their potential in vivo applications as neuronal interface with the biomimetic exoskeleton/exoprostheses.

BiomimeticsVol. 11(2)
University of Patras (GR), Lodz University of Technology (PL), Christian-Albrechts-Universität zu Kiel (DE), National Institute for Research and Development in Microtechnologies (RO), National Hellenic Research Foundation (GR), Marie Curie (GB)
Partnerships for the goals
Openalex Percentile: Top 55%
Neuroscience and Neural Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.