Nanoarchitectonics of aptamer-based electrochemical sensor using electrospun carbon nanofibers and Au nanoparticles for cd (II) analysis

Cadmium(II) is recognized as a hazardous heavy metal with severe implications for both the environment and human health. Traditional detection techniques, including atomic absorption spectroscopy and mass spectrometry, tend to be labor-intensive and require sophisticated instrumentation. In this study, we introduce a new electrochemical biosensor constructed from electrospun carbon nanofibers (CNFs) and gold nanoparticles (AuNPs) for the rapid and sensitive identification of Cd(II). The CNFs were synthesized from polyacrylonitrile (PAN) via a two-step thermal process involving stabilization and carbonization, and their structure was validated through X-ray diffraction and Raman spectroscopy. The synthesized nanofibers were utilized to modify the surface of a screen-printed carbon electrode (SPCE), followed by the electrodeposition of AuNPs to enhance its electrochemical performance. The surface morphology and elemental composition of the modified electrode were characterized using field emission scanning electron microscopy (FESEM) and energy-dispersive X-ray spectroscopy (EDS). A cadmium-selective aptamer was immobilized on the electrode and assessed using cyclic voltammetry (CV). The finalized aptasensor demonstrated a linear detection range from 0.5 to 10 ppb for Cd(II), achieving a detection limit of 0.05 ppb as measured by differential pulse voltammetry (DPV). The relative standard deviation (RSD) values for repeatability and reproducibility were about 3.2% and 3.5%, respectively. Therefore, this aptasensor can be considered as a promising tool for accurate environmental monitoring of Cd(II).

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-02-16
DOI
https://doi.org/10.1038/s41598-026-39085-3
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nanoarchitectonics of aptamer-based electrochemical sensor using electrospun carbon nanofibers and Au nanoparticles for cd (II) analysis

Sedigheh Niknam, Mehdi Shabani‐Nooshabadi, Mahdi Adabi
Scientific Reports
Advanced biosensing and bioanalysis techniques
article

Nanoarchitectonics of aptamer-based electrochemical sensor using electrospun carbon nanofibers and Au nanoparticles for cd (II) analysis

Sedigheh Niknam, Mehdi Shabani‐Nooshabadi, Mahdi Adabi
article en

Abstract

Cadmium(II) is recognized as a hazardous heavy metal with severe implications for both the environment and human health. Traditional detection techniques, including atomic absorption spectroscopy and mass spectrometry, tend to be labor-intensive and require sophisticated instrumentation. In this study, we introduce a new electrochemical biosensor constructed from electrospun carbon nanofibers (CNFs) and gold nanoparticles (AuNPs) for the rapid and sensitive identification of Cd(II). The CNFs were synthesized from polyacrylonitrile (PAN) via a two-step thermal process involving stabilization and carbonization, and their structure was validated through X-ray diffraction and Raman spectroscopy. The synthesized nanofibers were utilized to modify the surface of a screen-printed carbon electrode (SPCE), followed by the electrodeposition of AuNPs to enhance its electrochemical performance. The surface morphology and elemental composition of the modified electrode were characterized using field emission scanning electron microscopy (FESEM) and energy-dispersive X-ray spectroscopy (EDS). A cadmium-selective aptamer was immobilized on the electrode and assessed using cyclic voltammetry (CV). The finalized aptasensor demonstrated a linear detection range from 0.5 to 10 ppb for Cd(II), achieving a detection limit of 0.05 ppb as measured by differential pulse voltammetry (DPV). The relative standard deviation (RSD) values for repeatability and reproducibility were about 3.2% and 3.5%, respectively. Therefore, this aptasensor can be considered as a promising tool for accurate environmental monitoring of Cd(II).

Scientific ReportsVol. 16(1)
University of Kashan (IR), Tehran University of Medical Sciences (IR)
University of Kashan
Openalex Percentile: Top 54%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.