AI-assisted video analysis of the Trendelenburg test: a feasibility study

The Trendelenburg test is widely used to assess hip abductor function, but interpretation is typically subjective and only moderately reliable. Compensatory trunk lean can mask subtle pelvic drop, further limiting diagnostic accuracy. Artificial intelligence (AI) based markerless motion analysis allows objective quantification of pelvic, trunk, and knee angles using standard video recordings. This single-centre cross-sectional feasibility study was conducted in an Irish orthopaedic unit. Twelve adults were enrolled: seven post-total hip arthroplasty (THA) and five with native hip pathology. Each patient performed a standardised single-leg Trendelenburg test on both legs while being recorded with a single posteriorly placed smartphone camera. Videos were analysed offline using an AI-based markerless motion application (OnForm) to derive coronal-plane pelvic obliquity, trunk lean, and knee angle change between bipedal and single-leg stance. Continuous outcomes were summarised as medians with interquartile ranges (IQR) and ranges. Pre-specified thresholds (pelvic drop ≥ 4°, trunk lean ≥ 5°, knee angle change ≥ 3°) were used to describe the frequency of marked deviations. All patients completed the protocol with analysable recordings. The median video capture time was 32.5 s (IQR 23.5-36.0; range 19-42) and the median analysis time was 184.5 s (IQR 178.5-196.5; range 168-207), giving a median total workflow time of 215.5 s (IQR 203.5-232.5; range 193-244) per patient. Median worst contralateral pelvic obliquity was 0.0° (IQR - 1.0° to + 1.5°; range - 5° to + 6°). Median maximum trunk lean was 4.5° (IQR 2.8°-9.0°; range 2°-10°). Median coronal-plane knee angle change was 3.0° (IQR 2.0°-4.0°; range 1°-8°). Post-THA patients showed greater trunk compensation than those with native hips (median maximal trunk lean 9.0° vs 3.0°; median difference 6.0°), with trunk lean ≥ 5° in 5/7 post-THA and 1/5 native-hip patients. Knee deviations ≥ 3° were seen in 8 patients (67%). AI-assisted single-camera analysis of the Trendelenburg test is feasible, rapid, and clinically informative. The method consistently quantified pelvic, trunk, and knee angles and demonstrated that post-THA patients frequently compensate with trunk lean rather than contralateral pelvic drop. This approach could enhance objective documentation of Trendelenburg performance and support postoperative rehabilitation monitoring. These findings are preliminary and hypothesis-generating; larger controlled studies with asymptomatic controls and reference standards are required to validate accuracy and clinical utility.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-02-16
DOI
https://doi.org/10.1038/s41598-026-38980-z
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

AI-assisted video analysis of the Trendelenburg test: a feasibility study

Kate O'Sullivan, Conor Kilkenny, Eogháin Quinn, Gordan Daly et al.
Scientific Reports
Orthopaedic implants and arthroplasty
article

AI-assisted video analysis of the Trendelenburg test: a feasibility study

Kate O'Sullivan, Conor Kilkenny, Eogháin Quinn, Gordan Daly, Tom Doyle, Aiden Devitt
article en

Abstract

The Trendelenburg test is widely used to assess hip abductor function, but interpretation is typically subjective and only moderately reliable. Compensatory trunk lean can mask subtle pelvic drop, further limiting diagnostic accuracy. Artificial intelligence (AI) based markerless motion analysis allows objective quantification of pelvic, trunk, and knee angles using standard video recordings. This single-centre cross-sectional feasibility study was conducted in an Irish orthopaedic unit. Twelve adults were enrolled: seven post-total hip arthroplasty (THA) and five with native hip pathology. Each patient performed a standardised single-leg Trendelenburg test on both legs while being recorded with a single posteriorly placed smartphone camera. Videos were analysed offline using an AI-based markerless motion application (OnForm) to derive coronal-plane pelvic obliquity, trunk lean, and knee angle change between bipedal and single-leg stance. Continuous outcomes were summarised as medians with interquartile ranges (IQR) and ranges. Pre-specified thresholds (pelvic drop ≥ 4°, trunk lean ≥ 5°, knee angle change ≥ 3°) were used to describe the frequency of marked deviations. All patients completed the protocol with analysable recordings. The median video capture time was 32.5 s (IQR 23.5-36.0; range 19-42) and the median analysis time was 184.5 s (IQR 178.5-196.5; range 168-207), giving a median total workflow time of 215.5 s (IQR 203.5-232.5; range 193-244) per patient. Median worst contralateral pelvic obliquity was 0.0° (IQR - 1.0° to + 1.5°; range - 5° to + 6°). Median maximum trunk lean was 4.5° (IQR 2.8°-9.0°; range 2°-10°). Median coronal-plane knee angle change was 3.0° (IQR 2.0°-4.0°; range 1°-8°). Post-THA patients showed greater trunk compensation than those with native hips (median maximal trunk lean 9.0° vs 3.0°; median difference 6.0°), with trunk lean ≥ 5° in 5/7 post-THA and 1/5 native-hip patients. Knee deviations ≥ 3° were seen in 8 patients (67%). AI-assisted single-camera analysis of the Trendelenburg test is feasible, rapid, and clinically informative. The method consistently quantified pelvic, trunk, and knee angles and demonstrated that post-THA patients frequently compensate with trunk lean rather than contralateral pelvic drop. This approach could enhance objective documentation of Trendelenburg performance and support postoperative rehabilitation monitoring. These findings are preliminary and hypothesis-generating; larger controlled studies with asymptomatic controls and reference standards are required to validate accuracy and clinical utility.

Scientific ReportsVol. 16(1)
Royal College of Surgeons in Ireland (IE), University Hospital Galway (IE)
University of Galway
Openalex Percentile: Top 54%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.