Interfacial Electric Locking of the Aptamer Conformation for Accurate Liquid Biopsy Detection

The binding affinity of aptamer, which plays a key role in aptamer-based liquid biopsy, is affected by the unstable aptamer conformation. Existing strategies enhancing the binding affinity are complex, time-consuming, not easily generalizable, and lack universality to different aptamers. Herein, we discovered an interfacial electric locking effect and developed a universal strategy to stabilize aptamer conformations at the semiconductor-liquid interface. A positive liquid gate voltage redistributes the ions, forming a positively charged environment with an increasing cation concentration at the interface. The positive environment and the ionic interaction between the cations and phosphate backbone locks the aptamer conformation, decreasing the dissociation constant down to 10<sup>-10</sup> M with universality to different aptamers. The platform based on this strategy monitors a wide range of analytes in less than 5 min with a lowest limit of detection down to 10<sup>-20</sup> M. With such ultrasensitive detection capability, the platform demonstrates a robust classification accuracy of 98.6% in 51 clinical samples of bladder cancer.

Authors

Institutions

Publication Details

Journal
Nano Letters
Published
2026-02-16
DOI
https://doi.org/10.1021/acs.nanolett.5c05080
Primary Topic
Nanopore and Nanochannel Transport Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Interfacial Electric Locking of the Aptamer Conformation for Accurate Liquid Biopsy Detection

Yanan Tang, Renxing Huang, Shen Zhang, Changhao Dai et al.
Nano Letters
Nanopore and Nanochannel Transport Studies
article

Interfacial Electric Locking of the Aptamer Conformation for Accurate Liquid Biopsy Detection

Yanan Tang, Renxing Huang, Shen Zhang, Changhao Dai, Hongwenjie Ma, Xuejun Wang, C. L. Philip Chen, Yunqi Liu, Huimin Niu, Derong Kong, Yi Yang, Juan Li, Jie Wang
article en

Abstract

The binding affinity of aptamer, which plays a key role in aptamer-based liquid biopsy, is affected by the unstable aptamer conformation. Existing strategies enhancing the binding affinity are complex, time-consuming, not easily generalizable, and lack universality to different aptamers. Herein, we discovered an interfacial electric locking effect and developed a universal strategy to stabilize aptamer conformations at the semiconductor-liquid interface. A positive liquid gate voltage redistributes the ions, forming a positively charged environment with an increasing cation concentration at the interface. The positive environment and the ionic interaction between the cations and phosphate backbone locks the aptamer conformation, decreasing the dissociation constant down to 10<sup>-10</sup> M with universality to different aptamers. The platform based on this strategy monitors a wide range of analytes in less than 5 min with a lowest limit of detection down to 10<sup>-20</sup> M. With such ultrasensitive detection capability, the platform demonstrates a robust classification accuracy of 98.6% in 51 clinical samples of bladder cancer.

Nano LettersVol. 26(7)
Fujian Medical University (CN), Chinese Academy of Sciences (CN), Fudan University (CN), Zhejiang Cancer Hospital (CN), Fuzhou General Hospital of Nanjing Military Command (CN), Zhongshan Hospital (CN), Advanced Energy Materials (United States) (US), Nanjing University (CN)
Openalex Percentile: Top 54%
Nanopore and Nanochannel Transport Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.