HU-to-density calibration curves using diagnostic CT for radiotherapy treatment planning: a feasibility study

<i>Objective.</i>Accurate radiotherapy (RT) dose calculation critically depends on reliable conversion of Hounsfield units (HUs) to density, traditionally achieved through scanner-specific calibration using dedicated simulation computed tomography (CT) systems. This study aimed to derive and validate proposed HU-to-density calibration curves (PCTs) from multi-vendor diagnostic CT (dCT) data, independent of scanner and acquisition parameters.<i>Approach.</i>Both HU-to-relative electron density (RED) and mass density (MD) calibration curves were generated using the CIRS 062 M phantom scanned on eight multi-vendor CT systems at 80-140 kilovoltage-peak (kV<sub>p</sub>), including dual-energy modes. PCT (PCT-RED, PCT-MD) were derived by piecewise regression across the multi-kV<sub>p</sub>dataset. 20 palliative 6 MV flattening-filter-free (FFF) volumetric modulated arc therapy and intensity-modulated RT plans were recalculated in Eclipse v18 using all these curves with Acuros XB (dose-to-medium, MD-based) and the anisotropic analytical algorithm (RED-based). Dosimetric comparisons assessed: (1) PCT validation versus scanner-kV<sub>p</sub>-specific calibrations; (2) intra-scanner effects of varying kV<sub>p</sub>(versus 120/110 kV<sub>p</sub>per scanner). Evaluation included dose-volume histogram (DVH) metrics-planning target volume, organs at risk (OARs), body maximum dose, conformity index-and 3D<i>γ</i>analysis (2%/2 mm, 1%/1 mm) between calculated dose distributions. Statistical differences were assessed using the Wilcoxon signed-rank test (<i>α</i>= 0.05) with effect sizes.<i>Main results.</i>Differences between plan dose distributions obtained with PCT and those from scanner-specific curves were minimal. Although several DVH metrics were statistically different (<i>p</i>< 0.05), all differences remained within clinical acceptability. Across both PCT validation and intra-scanner kV<sub>p</sub>variation scenarios, median dosimetric differences were < 1.0% for both targets and OARs, regardless of HU variability. All plans achieved<i>γ</i>passing rates > 99% (1%/1 mm), confirming robustness.<i>Significance.</i>We propose a CT calibration model based on dCT for RT. This multi-vendor approach provides default curves when scanner-specific calibration is impractical, facilitating resource-efficient, simulation-free RT workflows via dCT-based treatment planning, while maintaining dosimetric accuracy across the evaluated dataset.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2026-02-16
DOI
https://doi.org/10.1088/1361-6560/ae4668
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

HU-to-density calibration curves using diagnostic CT for radiotherapy treatment planning: a feasibility study

Antonio Javier García Sánchez, Jonathan Suárez Arteaga, David Ramos Amores, Miguel Martínez Albaladejo et al.
Physics in Medicine and Biology
Advanced Radiotherapy Techniques
article

HU-to-density calibration curves using diagnostic CT for radiotherapy treatment planning: a feasibility study

Antonio Javier García Sánchez, Jonathan Suárez Arteaga, David Ramos Amores, Miguel Martínez Albaladejo, Alfredo Serna, Francisco Martínez Sánchez
article en

Abstract

<i>Objective.</i>Accurate radiotherapy (RT) dose calculation critically depends on reliable conversion of Hounsfield units (HUs) to density, traditionally achieved through scanner-specific calibration using dedicated simulation computed tomography (CT) systems. This study aimed to derive and validate proposed HU-to-density calibration curves (PCTs) from multi-vendor diagnostic CT (dCT) data, independent of scanner and acquisition parameters.<i>Approach.</i>Both HU-to-relative electron density (RED) and mass density (MD) calibration curves were generated using the CIRS 062 M phantom scanned on eight multi-vendor CT systems at 80-140 kilovoltage-peak (kV<sub>p</sub>), including dual-energy modes. PCT (PCT-RED, PCT-MD) were derived by piecewise regression across the multi-kV<sub>p</sub>dataset. 20 palliative 6 MV flattening-filter-free (FFF) volumetric modulated arc therapy and intensity-modulated RT plans were recalculated in Eclipse v18 using all these curves with Acuros XB (dose-to-medium, MD-based) and the anisotropic analytical algorithm (RED-based). Dosimetric comparisons assessed: (1) PCT validation versus scanner-kV<sub>p</sub>-specific calibrations; (2) intra-scanner effects of varying kV<sub>p</sub>(versus 120/110 kV<sub>p</sub>per scanner). Evaluation included dose-volume histogram (DVH) metrics-planning target volume, organs at risk (OARs), body maximum dose, conformity index-and 3D<i>γ</i>analysis (2%/2 mm, 1%/1 mm) between calculated dose distributions. Statistical differences were assessed using the Wilcoxon signed-rank test (<i>α</i>= 0.05) with effect sizes.<i>Main results.</i>Differences between plan dose distributions obtained with PCT and those from scanner-specific curves were minimal. Although several DVH metrics were statistically different (<i>p</i>< 0.05), all differences remained within clinical acceptability. Across both PCT validation and intra-scanner kV<sub>p</sub>variation scenarios, median dosimetric differences were < 1.0% for both targets and OARs, regardless of HU variability. All plans achieved<i>γ</i>passing rates > 99% (1%/1 mm), confirming robustness.<i>Significance.</i>We propose a CT calibration model based on dCT for RT. This multi-vendor approach provides default curves when scanner-specific calibration is impractical, facilitating resource-efficient, simulation-free RT workflows via dCT-based treatment planning, while maintaining dosimetric accuracy across the evaluated dataset.

Physics in Medicine and BiologyVol. 71(4)
Universidad Politécnica de Cartagena (ES), Santa Lucía University General Hospital (ES), Universidad de Murcia (ES)
Good health and well-being
Openalex Percentile: Top 48%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.