Beam Drift Mitigation and Wide-Range Measurement in a Miniaturized Ultrasonic Gas Flowmeter

To mitigate acoustic beam drift, which degrades the signal-to-noise ratio (SNR) and limits the measurement range in ultrasonic gas flowmeters (USFMs), we present a miniaturized transit-time USFM that integrates a single piezoelectric micromachined ultrasonic transducer (PMUT) with a non-axisymmetric conical cavity. This design increases acoustic transmission gain and produces anisotropic directivity across orthogonal radiation planes, thereby broadening acoustic coverage along the flow direction and reducing beam steering. With an optimized cavity angle combination of (50°, 70°), the system achieves a 7.4 dB transmission gain and a half-power beamwidth (HPBW) of 29.1°. Experimental validation demonstrates a sound pressure attenuation of only 0.72 dB at 18.74 m/s. Within the 0.06-12 m<sup>3</sup>/h flow range, the USFM exhibits indication errors of ±2% (<1 m<sup>3</sup>/h) and ±1.5% (≥1 m<sup>3</sup>/h), with repeatability below 0.5%. The performance meets the Class 1.5 accuracy standard specified in CJ/T 477-2015, offering an innovative solution for wide-range miniaturized gas flow measurement.

Authors

Institutions

Publication Details

Journal
Micromachines
Published
2026-02-16
DOI
https://doi.org/10.3390/mi17020254
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Beam Drift Mitigation and Wide-Range Measurement in a Miniaturized Ultrasonic Gas Flowmeter

Xueying Xiu, Shanfeng Hou, Chengguang Liu, Haochen Lyu et al.
Micromachines
Flow Measurement and Analysis
article

Beam Drift Mitigation and Wide-Range Measurement in a Miniaturized Ultrasonic Gas Flowmeter

Xueying Xiu, Shanfeng Hou, Chengguang Liu, Haochen Lyu, Songsong Zhang
article en

Abstract

To mitigate acoustic beam drift, which degrades the signal-to-noise ratio (SNR) and limits the measurement range in ultrasonic gas flowmeters (USFMs), we present a miniaturized transit-time USFM that integrates a single piezoelectric micromachined ultrasonic transducer (PMUT) with a non-axisymmetric conical cavity. This design increases acoustic transmission gain and produces anisotropic directivity across orthogonal radiation planes, thereby broadening acoustic coverage along the flow direction and reducing beam steering. With an optimized cavity angle combination of (50°, 70°), the system achieves a 7.4 dB transmission gain and a half-power beamwidth (HPBW) of 29.1°. Experimental validation demonstrates a sound pressure attenuation of only 0.72 dB at 18.74 m/s. Within the 0.06-12 m<sup>3</sup>/h flow range, the USFM exhibits indication errors of ±2% (<1 m<sup>3</sup>/h) and ±1.5% (≥1 m<sup>3</sup>/h), with repeatability below 0.5%. The performance meets the Class 1.5 accuracy standard specified in CJ/T 477-2015, offering an innovative solution for wide-range miniaturized gas flow measurement.

MicromachinesVol. 17(2)
Rutgers, The State University of New Jersey (US), Shanghai University (CN), Mellanox Technologies (Israel) (IL)
Openalex Percentile: Top 53%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.