Optimized Design and Biomechanical Analysis of Novel Hollow-Porous Hip Prosthesis for Enhancing Bone–Implant Interactions

Abstract The increasing demand for total hip arthroplasty, driven by osteoarthritis in the elderly and trauma in younger patients, necessitates implants with high biocompatibility and mechanical longevity. Current metallic implants (titanium, cobalt–chromium) often lead to stress shielding due to their high stiffness compared to human cortical bone, resulting in bone resorption and aseptic loosening. In this study, a porous hip joint structure design is proposed to enhance the load-bearing capacity of the hip joint and mitigate shielding stress after surgery. The hip joint model examined in this article features an improved design, including a hollow head, a porous stem with varying hollow structures and densities, and a stem surrounded by a bone block. The finite element method (based on ansys software) is used to analyze the biomechanical behavior of the artificial hip joint and the interaction between the joint and surrounding bone during the activities of young patients, including daily activities and dynamic movements such as climbing stairs and playing sports. The results presented in this article include stress and deformation distribution on the joint components and the bone. In addition, the sliding distance and contact pressure between the joint components, between the joint and the bone, were also investigated. Wearing mechanics of the liner's surfaces when in contact with the cup and head are also examined. From the results obtained, the study has proposed several hip joint designs that ensure sufficient durability and reduce joint laxity during patient activities.

Authors

Institutions

Publication Details

Journal
Journal of Tribology
Published
2026-02-16
DOI
https://doi.org/10.1115/1.4071117
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimized Design and Biomechanical Analysis of Novel Hollow-Porous Hip Prosthesis for Enhancing Bone–Implant Interactions

Nam Bich Thi Le
Journal of Tribology
Orthopaedic implants and arthroplasty
article

Optimized Design and Biomechanical Analysis of Novel Hollow-Porous Hip Prosthesis for Enhancing Bone–Implant Interactions

Nam Bich Thi Le
article en

Abstract

Abstract The increasing demand for total hip arthroplasty, driven by osteoarthritis in the elderly and trauma in younger patients, necessitates implants with high biocompatibility and mechanical longevity. Current metallic implants (titanium, cobalt–chromium) often lead to stress shielding due to their high stiffness compared to human cortical bone, resulting in bone resorption and aseptic loosening. In this study, a porous hip joint structure design is proposed to enhance the load-bearing capacity of the hip joint and mitigate shielding stress after surgery. The hip joint model examined in this article features an improved design, including a hollow head, a porous stem with varying hollow structures and densities, and a stem surrounded by a bone block. The finite element method (based on ansys software) is used to analyze the biomechanical behavior of the artificial hip joint and the interaction between the joint and surrounding bone during the activities of young patients, including daily activities and dynamic movements such as climbing stairs and playing sports. The results presented in this article include stress and deformation distribution on the joint components and the bone. In addition, the sliding distance and contact pressure between the joint components, between the joint and the bone, were also investigated. Wearing mechanics of the liner's surfaces when in contact with the cup and head are also examined. From the results obtained, the study has proposed several hip joint designs that ensure sufficient durability and reduce joint laxity during patient activities.

Journal of TribologyVol. 148(5)
VinUniversity (VN), Hanoi University of Science and Technology (VN)
Openalex Percentile: Top 54%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.