Thorough biomechanical analysis of arterial response to EasyEndo-Lite staple rotation: a simulation study in abaqus

Understanding instrument-tissue interaction is vital for safe surgery. We used Abaqus to simulate arterial response to EasyEndo-Lite Staple rotation, focusing on abrupt motion and strain-rate effects. Sudden angular rotation produced high strain rates and peak stresses in the clamped arterial segment, reaching 1.4 MPa at 15° and ∼3.7 MPa at 30°. Rapid cessation of rotation increased forces by up to 28%, indicating elevated damage risk. The simulations provided detailed deformation and stress data across scenarios, demonstrating how optimizing instrument design and operating parameters could substantially reduce tissue trauma and improve surgical outcomes.

Authors

Institutions

Publication Details

Journal
Computer Methods in Biomechanics & Biomedical Engineering
Published
2026-02-16
DOI
https://doi.org/10.1080/10255842.2026.2631137
Primary Topic
Elasticity and Material Modeling
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thorough biomechanical analysis of arterial response to EasyEndo-Lite staple rotation: a simulation study in abaqus

D. Canadinç, Kutlu Ca, Ali Kimiaei, Pinar Çağan et al.
Computer Methods in Biomechanics & Biomedical Engineering
Elasticity and Material Modeling
article

Thorough biomechanical analysis of arterial response to EasyEndo-Lite staple rotation: a simulation study in abaqus

D. Canadinç, Kutlu Ca, Ali Kimiaei, Pinar Çağan, Azizeh Hosseinjany, Seyedehtina Safaei
article en

Abstract

Understanding instrument-tissue interaction is vital for safe surgery. We used Abaqus to simulate arterial response to EasyEndo-Lite Staple rotation, focusing on abrupt motion and strain-rate effects. Sudden angular rotation produced high strain rates and peak stresses in the clamped arterial segment, reaching 1.4 MPa at 15° and ∼3.7 MPa at 30°. Rapid cessation of rotation increased forces by up to 28%, indicating elevated damage risk. The simulations provided detailed deformation and stress data across scenarios, demonstrating how optimizing instrument design and operating parameters could substantially reduce tissue trauma and improve surgical outcomes.

Computer Methods in Biomechanics & Biomedical Engineering
Bahçeşehir University (TR), Advanced Materials Corporation (United States) (US), Mustafa Kemal University (TR)
Good health and well-being
Openalex Percentile: Top 55%
Elasticity and Material Modeling
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Thorough biomechanical analysis of arterial response to EasyEndo-Lite staple rotation: a simulation study in abaqus — D. Canadinç, Kutlu Ca, et al. · Computer Methods in Biomechanics & Biomedical Engineering (2026) | TGRS Research Map | TGRS