Biochemical profiling provides a low-cost and globally accessible method to detect falsified vaccines and insulin

For many decades, there have been numerous reported cases of falsified liquid medical products, including vaccine and insulin preparations worldwide, but to date, there has been a lack of affordable and accessible analytical methods for biological medicines and vaccine authenticity testing. A conventional clinical chemistry analyser (Abbott Architect c16000) was used to determine the concentrations of analytes in genuine liquid biological products (vaccines and insulin) and falsified vaccine surrogates. Eight analytes were measured for each sample: sodium, potassium, chloride, calcium, magnesium, phosphate, glucose and protein. Each genuine liquid product had unique concentrations of analytes when tested using the eight methods applied, allowing clear differentiation from the falsified surrogates. In a blinded study, reproducibility was significantly high when the samples were run intra- and inter-batch up to 9 times over 9 different days, and it was possible to identify most of the samples by analyte presence alone. Imprecision was < 1.0 CV% for ion-selective electrode methods and typically < 5 CV% for spectrophotometric methods. A decision tree was created which was able to identify all samples. We demonstrate for the first time that a conventional clinical chemistry analyser provides a low-cost method to accurately differentiate genuine products from falsified surrogate liquid medicines and vaccines. This novel method has the potential to be used globally due to widespread use of clinical chemistry analysers in hospitals across the world, including in low- and middle-income countries where many cases of falsified medicines have been identified.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-02-16
DOI
https://doi.org/10.1038/s41598-026-37281-9
Primary Topic
Pharmaceutical Quality and Counterfeiting
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biochemical profiling provides a low-cost and globally accessible method to detect falsified vaccines and insulin

Laura Gomez Fernandez, Hamid A. Merchant, John Walsby-Tickle, Sunil Gairola et al.
Scientific Reports
Pharmaceutical Quality and Counterfeiting
article

Biochemical profiling provides a low-cost and globally accessible method to detect falsified vaccines and insulin

Laura Gomez Fernandez, Hamid A. Merchant, John Walsby-Tickle, Sunil Gairola, Tehmina Bharucha, Hamid Merchant, Sarah C. Gilbert, James S. O. McCullagh, Shrikrishna R. Chunekar, Robert J. Stokes, Susan Morris, Isabelle Legge, Rajender Jena, Kundan D. Patil, Susanna Dunachie, Michelle Taylor-Siddons, Tim James, Céline Caillet, Benediktus Yohan Arman, Rutendo Kuwana, Bevin Gangadharan, Michael Deats, Paul N. Newton, Jennifer Brook
article en

Abstract

For many decades, there have been numerous reported cases of falsified liquid medical products, including vaccine and insulin preparations worldwide, but to date, there has been a lack of affordable and accessible analytical methods for biological medicines and vaccine authenticity testing. A conventional clinical chemistry analyser (Abbott Architect c16000) was used to determine the concentrations of analytes in genuine liquid biological products (vaccines and insulin) and falsified vaccine surrogates. Eight analytes were measured for each sample: sodium, potassium, chloride, calcium, magnesium, phosphate, glucose and protein. Each genuine liquid product had unique concentrations of analytes when tested using the eight methods applied, allowing clear differentiation from the falsified surrogates. In a blinded study, reproducibility was significantly high when the samples were run intra- and inter-batch up to 9 times over 9 different days, and it was possible to identify most of the samples by analyte presence alone. Imprecision was < 1.0 CV% for ion-selective electrode methods and typically < 5 CV% for spectrophotometric methods. A decision tree was created which was able to identify all samples. We demonstrate for the first time that a conventional clinical chemistry analyser provides a low-cost method to accurately differentiate genuine products from falsified surrogate liquid medicines and vaccines. This novel method has the potential to be used globally due to widespread use of clinical chemistry analysers in hospitals across the world, including in low- and middle-income countries where many cases of falsified medicines have been identified.

Scientific ReportsVol. 16(1)
Imperial College Healthcare NHS Trust (GB), University of East London (GB), Mahidol University (TH), The Francis Crick Institute (GB), Nuffield Orthopaedic Centre (GB), John Radcliffe Hospital (GB), Jakarta Theological Seminary (ID), Serum Institute of India (India) (IN), University of Oxford (GB), Research Complex at Harwell (GB), World Health Organization (CH), Mahidol Oxford Tropical Medicine Research Unit (TH), Agilent Technologies (United Kingdom) (GB), Oxford BioMedica (United Kingdom) (GB), Oxford University Hospitals NHS Trust (GB), Infectious Diseases Data Observatory (GB), Imperial College London (GB)
Wellcome Trust, National Institute for Health and Care Research, University of Oxford, Lembaga Pengelola Dana Pendidikan, Kementerian Pendidikan, Kebudayaan, Riset, dan Teknologi, Science and Technology Facilities Council
No poverty
Openalex Percentile: Top 57%
Pharmaceutical Quality and Counterfeiting
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.