Optimization analysis of gasification performance in Fushun-type retorting furnace based on CFD simulation and orthogonal experiments

• Plant-calibrated 3D CFD model predicts in-furnace temperatures within 8.4% (7.5% avg). • CFD with L 27 orthogonal design and ANOVA quantifies factor effects and interactions. • Increasing λ from 0.192 to 0.288 raises outlet temperature by ≈300 K and gasification efficiency by 10–15 percentage points. • Optimal window (λ = 0.24–0.28, 75–80°C air, ≥90 % steam) yields >80 % carbon conversion with near-max HHV. To improve gasification performance in Fushun-type retorting furnaces, a three-dimensional CFD model of the gasification section was developed using the Realizable k–ε turbulence model, a porous-medium description of the semicoke bed, and user-defined gas–solid reaction kinetics. Under a representative industrial condition (primary air temperature 80 °C, excess air ratio λ = 0.240, steam saturation 100 %), predicted temperatures at three elevations agree with thermocouple data with a maximum relative error of 8.4 %, confirming sufficient accuracy for engineering analysis. An L 27 orthogonal design with ANOVA was used to study the effects of λ (0.192–0.312), primary air temperature (65–90 °C) and steam saturation (75–100 %) on outlet syngas temperature, sensible enthalpy, higher heating value (HHV) and gasification efficiency. Increasing λ from 0.192 to 0.288 raises outlet temperature by about 300 K and gasification efficiency by 10–15 percentage points, while HHV peaks near λ ≈ 0.26 and then declines due to over-oxidation. Moderate air preheating from 65 to 80 °C increases sensible enthalpy by 40–60 kW, whereas further heating to 90 °C reduces HHV by 5–10 %. Raising steam saturation from 75 % to 100 % improves gasification efficiency by over 10 percentage points with a small temperature penalty. Range and ANOVA analyses consistently identify λ as the dominant factor; primary air temperature mainly governs HHV, with steam saturation providing secondary regulation. The CFD–orthogonal framework recommends an operating window of λ ≈ 0.24–0.28, primary air temperature 75–80 °C and steam saturation ≥ 90 %, yielding near-maximum HHV and gasification efficiency above 80 %.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2026-02-16
DOI
https://doi.org/10.1016/j.rineng.2026.109619
Primary Topic
Thermochemical Biomass Conversion Processes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization analysis of gasification performance in Fushun-type retorting furnace based on CFD simulation and orthogonal experiments

C. H. Wang, Zhiyong Hu, Yulin Yan, Shaohui Li
Results in Engineering
Thermochemical Biomass Conversion Processes
article

Optimization analysis of gasification performance in Fushun-type retorting furnace based on CFD simulation and orthogonal experiments

C. H. Wang, Zhiyong Hu, Yulin Yan, Shaohui Li
article en

Abstract

• Plant-calibrated 3D CFD model predicts in-furnace temperatures within 8.4% (7.5% avg). • CFD with L 27 orthogonal design and ANOVA quantifies factor effects and interactions. • Increasing λ from 0.192 to 0.288 raises outlet temperature by ≈300 K and gasification efficiency by 10–15 percentage points. • Optimal window (λ = 0.24–0.28, 75–80°C air, ≥90 % steam) yields >80 % carbon conversion with near-max HHV. To improve gasification performance in Fushun-type retorting furnaces, a three-dimensional CFD model of the gasification section was developed using the Realizable k–ε turbulence model, a porous-medium description of the semicoke bed, and user-defined gas–solid reaction kinetics. Under a representative industrial condition (primary air temperature 80 °C, excess air ratio λ = 0.240, steam saturation 100 %), predicted temperatures at three elevations agree with thermocouple data with a maximum relative error of 8.4 %, confirming sufficient accuracy for engineering analysis. An L 27 orthogonal design with ANOVA was used to study the effects of λ (0.192–0.312), primary air temperature (65–90 °C) and steam saturation (75–100 %) on outlet syngas temperature, sensible enthalpy, higher heating value (HHV) and gasification efficiency. Increasing λ from 0.192 to 0.288 raises outlet temperature by about 300 K and gasification efficiency by 10–15 percentage points, while HHV peaks near λ ≈ 0.26 and then declines due to over-oxidation. Moderate air preheating from 65 to 80 °C increases sensible enthalpy by 40–60 kW, whereas further heating to 90 °C reduces HHV by 5–10 %. Raising steam saturation from 75 % to 100 % improves gasification efficiency by over 10 percentage points with a small temperature penalty. Range and ANOVA analyses consistently identify λ as the dominant factor; primary air temperature mainly governs HHV, with steam saturation providing secondary regulation. The CFD–orthogonal framework recommends an operating window of λ ≈ 0.24–0.28, primary air temperature 75–80 °C and steam saturation ≥ 90 %, yielding near-maximum HHV and gasification efficiency above 80 %.

Results in EngineeringVol. 29
Liaoning Shihua University (CN)
Openalex Percentile: Top 55%
Thermochemical Biomass Conversion Processes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.