Doubly Curved Crystal Optic X-Ray Fluorescence for the Analysis of UO2 Fuel Pellets

Abstract There are many possible instrumental geometries for obtaining micro-X-ray fluorescence elemental information on materials. The use of spatial and spectral filtering is critical for elemental compositional analysis, mapping, and quantification. Nuclear materials offer an especially unique challenge during elemental analysis, as their emitted natural radiation increases detector noise. A solution to this issue is the use of doubly curved crystal optics within spectro­meters, as they not only filter out background radiation but only pass the on-axis X-ray energy of choice to the detector. As a result, there is a significant improvement in the sensitivity and detection limits afforded by the incorporation of these optics into the spectrometer. The work presented here demonstrates the applicability of a high-resolution X-ray spectrometer in the determination of the U content of UO2 fuel pellets and the improved elemental selectivity compared to other traditional, polycapillary-based, X-ray fluorescence spectrometer setups.

Authors

Institutions

Publication Details

Journal
Microscopy Today
Published
2025-12-26
DOI
https://doi.org/10.1093/mictod/qaaf118
Primary Topic
X-ray Spectroscopy and Fluorescence Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Doubly Curved Crystal Optic X-Ray Fluorescence for the Analysis of UO2 Fuel Pellets

Arjen van Veelen, Bryan Hunter, Joshua T. White, Nikolaus L. Cordes et al.
Microscopy Today
X-ray Spectroscopy and Fluorescence Analysis
article

Doubly Curved Crystal Optic X-Ray Fluorescence for the Analysis of UO2 Fuel Pellets

Arjen van Veelen, Bryan Hunter, Joshua T. White, Nikolaus L. Cordes, B. M. Patterson
article en

Abstract

Abstract There are many possible instrumental geometries for obtaining micro-X-ray fluorescence elemental information on materials. The use of spatial and spectral filtering is critical for elemental compositional analysis, mapping, and quantification. Nuclear materials offer an especially unique challenge during elemental analysis, as their emitted natural radiation increases detector noise. A solution to this issue is the use of doubly curved crystal optics within spectro­meters, as they not only filter out background radiation but only pass the on-axis X-ray energy of choice to the detector. As a result, there is a significant improvement in the sensitivity and detection limits afforded by the incorporation of these optics into the spectrometer. The work presented here demonstrates the applicability of a high-resolution X-ray spectrometer in the determination of the U content of UO2 fuel pellets and the improved elemental selectivity compared to other traditional, polycapillary-based, X-ray fluorescence spectrometer setups.

Microscopy TodayVol. 34(1)
Los Alamos National Laboratory (US)
Openalex Percentile: Top 23%
X-ray Spectroscopy and Fluorescence Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Doubly Curved Crystal Optic X-Ray Fluorescence for the Analysis of UO2 Fuel Pellets — Arjen van Veelen, Bryan Hunter, et al. · Microscopy Today (2025) | TGRS Research Map | TGRS