Solubilization of Phosphate Rock via Dielectric Barrier Discharge in the Aqueous Phase

ABSTRACT This study presents a sustainable approach for phosphate (PO 4 3 ⁻) solubilization from phosphate rock (PR) using a dielectric barrier discharge (DBD) plasma system. Reactive oxygen‐nitrogen species (RONS) were generated, and their effects on PR dissolution were investigated under varied voltages, currents, and air flow rates in the aqueous phase. Higher flow rates favored the acidulation pathway, while higher current‐density promoted the oxidation pathway; both contributed to solubilization. Optimal conditions (13 kV, 0.8 A, 5 L min⁻¹) yielded 85% dissolution, with 315 mg L⁻¹ NO 3 ⁻ and 44.5 mg L⁻¹ PO 4 3 ⁻. The quadratic model accurately predicted results (recovery > 90%). Compared with HNO₃‐only control (78% efficiency, 32.5 mg L⁻¹ PO 4 3 ⁻), DBD treatment achieved superior solubilization, offering an environmentally friendly perspective for PR solubilization.

Authors

Institutions

Publication Details

Journal
Plasma Processes and Polymers
Published
2026-02-01
DOI
https://doi.org/10.1002/ppap.70140
Primary Topic
Plasma Applications and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Solubilization of Phosphate Rock via Dielectric Barrier Discharge in the Aqueous Phase

Ulker Diler Keris‐Sen
Plasma Processes and Polymers
Plasma Applications and Diagnostics
article

Solubilization of Phosphate Rock via Dielectric Barrier Discharge in the Aqueous Phase

Ulker Diler Keris‐Sen
article en

Abstract

ABSTRACT This study presents a sustainable approach for phosphate (PO 4 3 ⁻) solubilization from phosphate rock (PR) using a dielectric barrier discharge (DBD) plasma system. Reactive oxygen‐nitrogen species (RONS) were generated, and their effects on PR dissolution were investigated under varied voltages, currents, and air flow rates in the aqueous phase. Higher flow rates favored the acidulation pathway, while higher current‐density promoted the oxidation pathway; both contributed to solubilization. Optimal conditions (13 kV, 0.8 A, 5 L min⁻¹) yielded 85% dissolution, with 315 mg L⁻¹ NO 3 ⁻ and 44.5 mg L⁻¹ PO 4 3 ⁻. The quadratic model accurately predicted results (recovery > 90%). Compared with HNO₃‐only control (78% efficiency, 32.5 mg L⁻¹ PO 4 3 ⁻), DBD treatment achieved superior solubilization, offering an environmentally friendly perspective for PR solubilization.

Plasma Processes and PolymersVol. 23(2)
Gebze Technical University (TR)
Openalex Percentile: Top 54%
Plasma Applications and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.