Optimizing design parameters to treat the hospital wastewater effluent using hybrid sono-Fenton-electrocoagulation processes

Abstract Combining electrochemical (EC) with advanced oxidation processes (AOPs) has shown considerable potential in water and wastewater treatment. The current study looked at treating hospital wastewater using the sono-Fenton-electrocoagulation (SF-EC) method with dual application of (Fe/Fe) electrodes to improve the removal of COD and nitrate. Numerous studies have so far employed various heterogeneous AOPs to remove the COD and nitrate from hospital wastewater (HWW). Nevertheless, the use of SF-EC based integrated procedures was not previously evaluated. It has been investigated how the pH of solution, treatment duration, H 2 O 2 , and current effect the elimination of COD and nitrate. The outcomes were optimized using central composite design (CCD), a special feature of the response surface methodology (RSM). The quadratic model was proposed for SF-EC process optimization. The COD and nitrate reductions were found to have R 2 values of 0.99 and 0.99, respectively, using the quadratic polynomial equation. The findings demonstrated that high removal efficiency 91.2 5 % for COD and 97.48 % for nitrate were obtained at pH of 9, treatment time of 50 min, H 2 O 2 concentration of 20 mg/L and current of 0.7 Amp and the lowest removal efficiency 34.32 % for COD and 38.36 % for nitrate was obtained at pH 3, treatment time 40 min, H 2 O 2 concentration 15 mg/L, and current 0.6 Amp. pH is a crucial factor, alongside H 2 O 2 , treatment time and current that directly affects COD and nitrate phosphate removal. The sono-Fenton-electrocoagulation process is considered a feasible treatment option for hospital wastewater since it has typically yielded positive results.

Authors

Institutions

Publication Details

Journal
International Journal of Chemical Reactor Engineering
Published
2026-02-01
DOI
https://doi.org/10.1515/ijcre-2025-0219
Primary Topic
Advanced oxidation water treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing design parameters to treat the hospital wastewater effluent using hybrid sono-Fenton-electrocoagulation processes

Perumal Asaithambi, Esayas Alemayehu, Meseret Endalew
International Journal of Chemical Reactor Engineering
Advanced oxidation water treatment
article

Optimizing design parameters to treat the hospital wastewater effluent using hybrid sono-Fenton-electrocoagulation processes

Perumal Asaithambi, Esayas Alemayehu, Meseret Endalew
article en

Abstract

Abstract Combining electrochemical (EC) with advanced oxidation processes (AOPs) has shown considerable potential in water and wastewater treatment. The current study looked at treating hospital wastewater using the sono-Fenton-electrocoagulation (SF-EC) method with dual application of (Fe/Fe) electrodes to improve the removal of COD and nitrate. Numerous studies have so far employed various heterogeneous AOPs to remove the COD and nitrate from hospital wastewater (HWW). Nevertheless, the use of SF-EC based integrated procedures was not previously evaluated. It has been investigated how the pH of solution, treatment duration, H 2 O 2 , and current effect the elimination of COD and nitrate. The outcomes were optimized using central composite design (CCD), a special feature of the response surface methodology (RSM). The quadratic model was proposed for SF-EC process optimization. The COD and nitrate reductions were found to have R 2 values of 0.99 and 0.99, respectively, using the quadratic polynomial equation. The findings demonstrated that high removal efficiency 91.2 5 % for COD and 97.48 % for nitrate were obtained at pH of 9, treatment time of 50 min, H 2 O 2 concentration of 20 mg/L and current of 0.7 Amp and the lowest removal efficiency 34.32 % for COD and 38.36 % for nitrate was obtained at pH 3, treatment time 40 min, H 2 O 2 concentration 15 mg/L, and current 0.6 Amp. pH is a crucial factor, alongside H 2 O 2 , treatment time and current that directly affects COD and nitrate phosphate removal. The sono-Fenton-electrocoagulation process is considered a feasible treatment option for hospital wastewater since it has typically yielded positive results.

International Journal of Chemical Reactor EngineeringVol. 24(2)
Jimma University (ET), Water and Land Resource Centre (ET), Addis Ababa University (ET), University of Rajasthan (IN)
Clean water and sanitation
Openalex Percentile: Top 57%
Advanced oxidation water treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.