Metal Artifact Reduction in Lumbar Spine Instrumentation

PCD CT with VMI 120 or iMAR achieved artifact reduction comparable to EID CT for lumbar spine metal artifact reduction, at nearly half the radiation dose. Combining VMI120 + iMAR provided the strongest qualitative and quantitative artifact reduction, but at the cost of the lowest cortical and trabecular bone visibility. 140 kVp acquisitions should be favored over 100 kVp acquisitions in PCD to reduce the occurrence of "dark zone" and "silhouette artifacts", suggesting a fixed tube voltage instead of an automatic tube voltage setting in instrumented lumbar spine imaging. VMI reconstruction of tin-filtered lumbar spine CT effectively reduces metal artifacts, with PCD favored over EID for its inherent spectral capabilities and the potential for substantial dose reduction.

Authors

Publication Details

Journal
Investigative Radiology
Published
2026-02-16
DOI
https://doi.org/10.1097/rli.0000000000001276
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Metal Artifact Reduction in Lumbar Spine Instrumentation

Daniel Nanz, Frederik Abel, Christoph Johannes Laux, Adrian A. Marth et al.
Investigative Radiology
Advanced X-ray and CT Imaging
article

Metal Artifact Reduction in Lumbar Spine Instrumentation

Daniel Nanz, Frederik Abel, Christoph Johannes Laux, Adrian A. Marth, Reto Sutter, Thomas Marth, Andreas Specovius, Roy Paul Marcus, Benjamin Fritz
article en

Abstract

PCD CT with VMI 120 or iMAR achieved artifact reduction comparable to EID CT for lumbar spine metal artifact reduction, at nearly half the radiation dose. Combining VMI120 + iMAR provided the strongest qualitative and quantitative artifact reduction, but at the cost of the lowest cortical and trabecular bone visibility. 140 kVp acquisitions should be favored over 100 kVp acquisitions in PCD to reduce the occurrence of "dark zone" and "silhouette artifacts", suggesting a fixed tube voltage instead of an automatic tube voltage setting in instrumented lumbar spine imaging. VMI reconstruction of tin-filtered lumbar spine CT effectively reduces metal artifacts, with PCD favored over EID for its inherent spectral capabilities and the potential for substantial dose reduction.

Investigative Radiology
Affordable and clean energy
Openalex Percentile: Top 55%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.