Shaeer’s corporotomy closure technique for safer suturing of the corpora: a randomized controlled study

Suturing the corporotomies over the penile implant yields water-tight closure, reducing the risk of hematoma and subsequent infection, though at the risk of needle puncture of the inflatable cylinders. This prospective randomized controlled study evaluates Shaeer's Corporotomy Closure Technique (SCCT); a surgical technique to enhance the ease and safety of suturing the corporotomies closed, by everting the corporotomy edges. The study was performed in a single center, between 2022 and 2025, in Cairo, Egypt. Three-piece inflatable penile prosthesis (iPP) implantation was performed for 32 patients with erectile dysfunction refractory to medical treatment, excluding cases of previous penile surgery, Peyronie's disease, corporal fibrosis or radical prostatectomy, or those receiving anticoagulant therapy. Patients were randomized into two groups. The Control Group had the corporotomies closed by tying the pre-placed stay sutures. SCCT Group had the corporotomies sutured closed with the edges everted using horizontal mattress sutures placed on each side of the intended corporotomy, two on each corpus cavernosum. After corporotomy, the stay sutures were tied, everting the edges. The everted corporotomy edges were then sutured closed in a running fashion. Operative time was 9.5% (5 min) shorter in the Control Group (47.7 ± 5.3 mins vs. 52.7 ± 4.4 mins, p = 0.009). Drain output at 24 h was 78.8% (59.4 cc's) higher for Control Group (75.4 ± 32.8 cc's vs. 16 ± 8.6 cc's, p < 0.001), (Table 1, Fig. 5). Total drain output was 81.5% (77.5 cc's) higher in Control Group (95.1 ± 64.8 cc's vs. 17.6 ± 12 cc's, p < 0.001). For both groups, no intra-operative complications, infections or device mechanical failures were recorded through the follow up period; 14 months ± 4.4. One case in Control Group developed a scrotal hematoma, and two cases developed scrotal tissue induration surrounding the pump, delaying deflation and cycling. SCCT allows safer suturing of the corporotomies.

Authors

Institutions

Publication Details

Journal
International Journal of Impotence Research
Published
2026-02-16
DOI
https://doi.org/10.1038/s41443-026-01225-8
Primary Topic
Sexual function and dysfunction studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Shaeer’s corporotomy closure technique for safer suturing of the corpora: a randomized controlled study

Kamal Shaeer, O Shaeer
International Journal of Impotence Research
Sexual function and dysfunction studies
article

Shaeer’s corporotomy closure technique for safer suturing of the corpora: a randomized controlled study

Kamal Shaeer, O Shaeer
article en

Abstract

Suturing the corporotomies over the penile implant yields water-tight closure, reducing the risk of hematoma and subsequent infection, though at the risk of needle puncture of the inflatable cylinders. This prospective randomized controlled study evaluates Shaeer's Corporotomy Closure Technique (SCCT); a surgical technique to enhance the ease and safety of suturing the corporotomies closed, by everting the corporotomy edges. The study was performed in a single center, between 2022 and 2025, in Cairo, Egypt. Three-piece inflatable penile prosthesis (iPP) implantation was performed for 32 patients with erectile dysfunction refractory to medical treatment, excluding cases of previous penile surgery, Peyronie's disease, corporal fibrosis or radical prostatectomy, or those receiving anticoagulant therapy. Patients were randomized into two groups. The Control Group had the corporotomies closed by tying the pre-placed stay sutures. SCCT Group had the corporotomies sutured closed with the edges everted using horizontal mattress sutures placed on each side of the intended corporotomy, two on each corpus cavernosum. After corporotomy, the stay sutures were tied, everting the edges. The everted corporotomy edges were then sutured closed in a running fashion. Operative time was 9.5% (5 min) shorter in the Control Group (47.7 ± 5.3 mins vs. 52.7 ± 4.4 mins, p = 0.009). Drain output at 24 h was 78.8% (59.4 cc's) higher for Control Group (75.4 ± 32.8 cc's vs. 16 ± 8.6 cc's, p < 0.001), (Table 1, Fig. 5). Total drain output was 81.5% (77.5 cc's) higher in Control Group (95.1 ± 64.8 cc's vs. 17.6 ± 12 cc's, p < 0.001). For both groups, no intra-operative complications, infections or device mechanical failures were recorded through the follow up period; 14 months ± 4.4. One case in Control Group developed a scrotal hematoma, and two cases developed scrotal tissue induration surrounding the pump, delaying deflation and cycling. SCCT allows safer suturing of the corporotomies.

International Journal of Impotence Research
Cairo University (EG)
Openalex Percentile: Top 58%
Sexual function and dysfunction studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Shaeer’s corporotomy closure technique for safer suturing of the corpora: a randomized controlled study — Kamal Shaeer, O Shaeer · International Journal of Impotence Research (2026) | TGRS Research Map | TGRS