Scleral Fixation of Intraocular Lenses: Outcomes From MA60AC Intraocular Lens Fixation With a 10-0 Prolene Suture vs Akreos Intraocular Lens Fixation With a Polytetrafluoroethylene (Gore-Tex) Suture

<b>Purpose:</b> To compare the outcomes of intraocular lens (IOL) scleral fixation using Akreos (Bausch + Lomb) lenses with polytetrafluoroethylene (Gore-Tex CV-8, W.L. Gore & Associates) sutures vs 3-piece IOLs (Alcon MA60AC) with 10-0 Prolene (Ethicon, a Johnson & Johnson Company) sutures. <b>Methods:</b> Patients undergoing pars plana vitrectomy between January 2019 and July 2021 were retrospectively selected regardless of the technique used. Patients who completed at least 6 months of follow-up were invited to a new clinic visit to evaluate outcomes of their procedures. The protocol included intraocular pressure assessment using a Goldmann tonometer, subjective refraction, corneal topography with a Pentacam HR (Oculus, Optikgeräte GmbH), IOL decentration assessment on biomicroscopy via slitlamp, and optic disc cupping evaluation by indirect ophthalmoscopy. Complications such as corneal edema, ocular hypertension, hypotony, hyphema, IOL decentration, cystoid macular edema, vitreous hemorrhage, suture breakage, retinal detachment, or uveitis-glaucoma-hyphema syndrome were investigated. <b>Results:</b> A total of 20 eyes from 20 participants were classified into 2 groups according to surgical technique: Akreos plus GoreTex (n=11) or MA60AC plus Prolene (n=9). The results showed no statistically significant differences between the 2 groups in terms of refractive outcomes, postoperative complications, or demographic variables, suggesting both techniques provide similar efficacy and safety. <b>Conclusions:</b> Both the Akreos with Gore-Tex and MA60AC with Prolene scleral fixation techniques are effective and safe for patients requiring IOL implantation in the absence of adequate capsular support. Further research is needed to solidify these observations and guide future clinical decisions.

Authors

Institutions

Publication Details

Journal
Journal of VitreoRetinal Diseases
Published
2026-02-16
DOI
https://doi.org/10.1177/24741264251412080
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Scleral Fixation of Intraocular Lenses: Outcomes From MA60AC Intraocular Lens Fixation With a 10-0 Prolene Suture vs Akreos Intraocular Lens Fixation With a Polytetrafluoroethylene (Gore-Tex) Suture

Rodrigo Brant, Arthur Gustavo Fernandes, Guilherme Marge De Aquino Guedes, Daniel Lani Louzada
Journal of VitreoRetinal Diseases
Intraocular Surgery and Lenses
article

Scleral Fixation of Intraocular Lenses: Outcomes From MA60AC Intraocular Lens Fixation With a 10-0 Prolene Suture vs Akreos Intraocular Lens Fixation With a Polytetrafluoroethylene (Gore-Tex) Suture

Rodrigo Brant, Arthur Gustavo Fernandes, Guilherme Marge De Aquino Guedes, Daniel Lani Louzada
article en

Abstract

<b>Purpose:</b> To compare the outcomes of intraocular lens (IOL) scleral fixation using Akreos (Bausch + Lomb) lenses with polytetrafluoroethylene (Gore-Tex CV-8, W.L. Gore & Associates) sutures vs 3-piece IOLs (Alcon MA60AC) with 10-0 Prolene (Ethicon, a Johnson & Johnson Company) sutures. <b>Methods:</b> Patients undergoing pars plana vitrectomy between January 2019 and July 2021 were retrospectively selected regardless of the technique used. Patients who completed at least 6 months of follow-up were invited to a new clinic visit to evaluate outcomes of their procedures. The protocol included intraocular pressure assessment using a Goldmann tonometer, subjective refraction, corneal topography with a Pentacam HR (Oculus, Optikgeräte GmbH), IOL decentration assessment on biomicroscopy via slitlamp, and optic disc cupping evaluation by indirect ophthalmoscopy. Complications such as corneal edema, ocular hypertension, hypotony, hyphema, IOL decentration, cystoid macular edema, vitreous hemorrhage, suture breakage, retinal detachment, or uveitis-glaucoma-hyphema syndrome were investigated. <b>Results:</b> A total of 20 eyes from 20 participants were classified into 2 groups according to surgical technique: Akreos plus GoreTex (n=11) or MA60AC plus Prolene (n=9). The results showed no statistically significant differences between the 2 groups in terms of refractive outcomes, postoperative complications, or demographic variables, suggesting both techniques provide similar efficacy and safety. <b>Conclusions:</b> Both the Akreos with Gore-Tex and MA60AC with Prolene scleral fixation techniques are effective and safe for patients requiring IOL implantation in the absence of adequate capsular support. Further research is needed to solidify these observations and guide future clinical decisions.

Journal of VitreoRetinal Diseases
University of Southern California (US), University of Calgary (CA), Southern California Eye Institute (US), Hospital São Paulo (BR), Universidade Federal de São Paulo (BR)
Openalex Percentile: Top 54%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.