Multimodal Fiber Somatosensory: Optical Fiber ‘Nerves’ Empower Continuum Surgical Robots With Multimodal Feedback

To achieve the force sensing at the sub-5 mm end effector of a continuum robot, optical fiber 'nerves' -incorporating the Fabry-Pérot (FP) cavity and step-etched fiber Bragg gratings (FBGs) was proposed to sense the multimodal forces (clamping force, 3-axis wrist force, and driving force) and shape awareness. The proposed laser-welded package solved the problem of clinical application adaptability, enabling the robot to withstand sterilization (15 cycles) and maintain an error of <5% over 60 days of operation. Combined with the in situ calibration method, the surgical robot can maintain high force measurement accuracy in cadaver specimens and live animal experiments. The master-slave teleoperation system with feedback of clamping and 3-axis wrist force also reduces the operation force by 30%-40%, improving the safety of surgical operations. The proposed method opens new avenues for developing smart surgical instruments with inherent sensing capabilities.

Authors

Institutions

Publication Details

Journal
Advanced Healthcare Materials
Published
2026-02-15
DOI
https://doi.org/10.1002/adhm.202504556
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multimodal Fiber Somatosensory: Optical Fiber ‘Nerves’ Empower Continuum Surgical Robots With Multimodal Feedback

Yi Xu, Jiajun Li, Haotian Zhou, Bo Xiao et al.
Advanced Healthcare Materials
Soft Robotics and Applications
article

Multimodal Fiber Somatosensory: Optical Fiber ‘Nerves’ Empower Continuum Surgical Robots With Multimodal Feedback

Yi Xu, Jiajun Li, Haotian Zhou, Bo Xiao, Aiguo Song, Yongwen ZHU, Fan Hong, Yi-Xiang Wang, Zude Zhou Zude Zhou, Xu Zhang, Tianliang Li, Hongliang Ren, Houxin Tu, Chen Zhao
article en

Abstract

To achieve the force sensing at the sub-5 mm end effector of a continuum robot, optical fiber 'nerves' -incorporating the Fabry-Pérot (FP) cavity and step-etched fiber Bragg gratings (FBGs) was proposed to sense the multimodal forces (clamping force, 3-axis wrist force, and driving force) and shape awareness. The proposed laser-welded package solved the problem of clinical application adaptability, enabling the robot to withstand sterilization (15 cycles) and maintain an error of <5% over 60 days of operation. Combined with the in situ calibration method, the surgical robot can maintain high force measurement accuracy in cadaver specimens and live animal experiments. The master-slave teleoperation system with feedback of clamping and 3-axis wrist force also reduces the operation force by 30%-40%, improving the safety of surgical operations. The proposed method opens new avenues for developing smart surgical instruments with inherent sensing capabilities.

Advanced Healthcare Materials
Chinese University of Hong Kong (HK), Wuhan University of Technology (CN), Wuhan University (CN), Southeast University (BD), Renmin Hospital of Wuhan University (CN), Xi’an Jiaotong-Liverpool University (CN), Southeast University (CN)
Openalex Percentile: Top 55%
Soft Robotics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies