Fault Location and Calibration of Multi-Terminal DC Ring Network Based on Traveling Wave Redundant Information

Traditional single-ended traveling wave fault location is sensitive to velocity uncertainty, complex topologies, and variations in the equivalent impedance of converter stations. This paper proposes a fault distance calibration method based on the fusion of traveling wave redundant information and inverse weighting: multiple sets of initial distance estimates are formed using wave fronts arrival times measured at multiple terminals. These estimates are then calibrated through inverse weighting fusion according to the error sensitivity of each redundant observation, thereby suppressing errors caused by wave velocity deviations and structural inhomogeneities. Simulation verification using PSCAD/EMTDC for a four-terminal VSC-MTDC loop network demonstrates that this method reduces dependence on precise wave velocity measurements while enhancing the accuracy and robustness of DC loop network fault location.

Authors

Institutions

Publication Details

Journal
Eng—Advances in Engineering
Published
2026-02-14
DOI
https://doi.org/10.3390/eng7020089
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fault Location and Calibration of Multi-Terminal DC Ring Network Based on Traveling Wave Redundant Information

Fangming Deng, Yuzhe Liu, Wenxian Chen, Zewen Li
Eng—Advances in Engineering
HVDC Systems and Fault Protection
article

Fault Location and Calibration of Multi-Terminal DC Ring Network Based on Traveling Wave Redundant Information

Fangming Deng, Yuzhe Liu, Wenxian Chen, Zewen Li
article en

Abstract

Traditional single-ended traveling wave fault location is sensitive to velocity uncertainty, complex topologies, and variations in the equivalent impedance of converter stations. This paper proposes a fault distance calibration method based on the fusion of traveling wave redundant information and inverse weighting: multiple sets of initial distance estimates are formed using wave fronts arrival times measured at multiple terminals. These estimates are then calibrated through inverse weighting fusion according to the error sensitivity of each redundant observation, thereby suppressing errors caused by wave velocity deviations and structural inhomogeneities. Simulation verification using PSCAD/EMTDC for a four-terminal VSC-MTDC loop network demonstrates that this method reduces dependence on precise wave velocity measurements while enhancing the accuracy and robustness of DC loop network fault location.

Eng—Advances in EngineeringVol. 7(2)
East China Jiaotong University (CN)
National Natural Science Foundation of China, Natural Science Foundation of Jiangxi Province
Openalex Percentile: Top 55%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fault Location and Calibration of Multi-Terminal DC Ring Network Based on Traveling Wave Redundant Information — Fangming Deng, Yuzhe Liu, et al. · Eng—Advances in Engineering (2026) | TGRS Research Map | TGRS