Advancing Dry Electroencephalography With Scalable, Soft, and Transcranial Magnetic Stimulation‐Compatible Ti <sub>3</sub> C <sub>2</sub> T <sub>x</sub> MXene Electrodes for Research and Clinical‐Grade Applications

Electroencephalography (EEG), essential for diagnosing and researching neurological disorders, utilizes gelled electrodes, which present limitations in safety, comfort, stability, and usability, particularly in long-term applications. We introduce a novel dry EEG technology using soft, porous, low-impedance, Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub> MXene electrodes. The 10 Hz impedance of these electrodes across scalp locations is 2.1 ± 1.8 kΩ, comparable to gelled Ag/AgCl electrodes and below clinical thresholds. Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub> electrodes maintain stable impedance over 4.5 h on agarose phantoms and retain structure after 50 cycles of 80% axial compression. These electrodes are suitable for simultaneous EEG and transcranial magnetic stimulation (TMS), exhibiting no significant displacement, heating, or unsafe charge densities under TMS fields. We benchmarked dry electrodes across recording scenarios and hair types against gelled electrodes. In full-scalp steady-state visual evoked potential (SSVEP) recordings, gelled and Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub> electrodes were highly correlated (R > 0.89). Clinical EEG with Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub> electrodes captured all features observed with gelled electrodes (R > 0.84) and was rated for clinical quality by neurologists. Furthermore, dry MXene EEG electrode recorded high-quality EEG for over 4 h. In mobile EEG, Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub> electrodes did not induce signal distortions and enabled task-specific feature detection with a comparable signal-to-noise ratio to gelled electrodes. These findings establish dry Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub> electrodes as an alternative to gel-based systems, with broad potential in clinical diagnostics and research.

Authors

Institutions

Publication Details

Journal
Advanced Science
Published
2026-02-15
DOI
https://doi.org/10.1002/advs.202511486
Primary Topic
Neurological disorders and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advancing Dry Electroencephalography With Scalable, Soft, and Transcranial Magnetic Stimulation‐Compatible Ti 3 C 2 T x MXene Electrodes for Research and Clinical‐Grade Applications

Francesca Cimino, Flavia Vitale, Raghav Garg, Ryan Rich et al.
Advanced Science
Neurological disorders and treatments
article

Advancing Dry Electroencephalography With Scalable, Soft, and Transcranial Magnetic Stimulation‐Compatible Ti 3 C 2 T x MXene Electrodes for Research and Clinical‐Grade Applications

Francesca Cimino, Flavia Vitale, Raghav Garg, Ryan Rich, Spencer R. Averbeck, Sneha Shankar, Doris Xu, Mariam Josyula, Nina Petillo, Jakob Michiels, Ashley Koluda, John D Medaglia, Brian Erickson, Ksenija Tasich, Kathryn A. Davis, Daryl Hurwitz, James J. Gugger, Eugenia Angelopoulos
article en

Abstract

Electroencephalography (EEG), essential for diagnosing and researching neurological disorders, utilizes gelled electrodes, which present limitations in safety, comfort, stability, and usability, particularly in long-term applications. We introduce a novel dry EEG technology using soft, porous, low-impedance, Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub> MXene electrodes. The 10 Hz impedance of these electrodes across scalp locations is 2.1 ± 1.8 kΩ, comparable to gelled Ag/AgCl electrodes and below clinical thresholds. Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub> electrodes maintain stable impedance over 4.5 h on agarose phantoms and retain structure after 50 cycles of 80% axial compression. These electrodes are suitable for simultaneous EEG and transcranial magnetic stimulation (TMS), exhibiting no significant displacement, heating, or unsafe charge densities under TMS fields. We benchmarked dry electrodes across recording scenarios and hair types against gelled electrodes. In full-scalp steady-state visual evoked potential (SSVEP) recordings, gelled and Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub> electrodes were highly correlated (R > 0.89). Clinical EEG with Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub> electrodes captured all features observed with gelled electrodes (R > 0.84) and was rated for clinical quality by neurologists. Furthermore, dry MXene EEG electrode recorded high-quality EEG for over 4 h. In mobile EEG, Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub> electrodes did not induce signal distortions and enabled task-specific feature detection with a comparable signal-to-noise ratio to gelled electrodes. These findings establish dry Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub> electrodes as an alternative to gel-based systems, with broad potential in clinical diagnostics and research.

Advanced Science
Institute of Cognitive and Brain Sciences (US), Translational Therapeutics (United States) (US), Philadelphia VA Medical Center (US), University of Rochester (US), Drexel University (US), University of Pennsylvania (US)
Openalex Percentile: Top 58%
Neurological disorders and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.