Processed EEG Artifacts and Pitfalls: A Narrative Review and a Troubleshooting Mnemonic

Processed electroencephalography (EEG) is widely used for depth of anesthesia monitoring. However, multiple interference sources can distort raw EEG data, leading to misinterpretation of quantitative EEG (qEEG) indices, potentially resulting in insufficient or excessive depth of anesthesia or burst suppression. This review summarizes qEEG interference and artifact sources, as well as some paradoxical effects and pitfalls, reported in the literature. These factors can be categorized into pharmacological, electromagnetic and mechanical, pathophysiological, and model-related sources. When unexpected qEEG values lack an immediately apparent explanation, a structured approach can be valuable, particularly in complex circumstances. We provide a relatable mnemonic "ANESTHESIA" for troubleshooting potential interference sources. If artifact removal is impractical, this should be acknowledged when adjusting the anesthetic management plan. A systematic approach to identify qEEG artifacts and acknowledge potential pitfalls may improve the reliability of depth of anesthesia monitoring, ultimately enhancing patient safety.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2026-02-15
DOI
https://doi.org/10.7759/cureus.103656
Primary Topic
Anesthesia and Sedative Agents
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Processed EEG Artifacts and Pitfalls: A Narrative Review and a Troubleshooting Mnemonic

Vasyl Katerenchuk, Alexandre Calçada, Ana Correia Batista, Rita Regufe et al.
Cureus
Anesthesia and Sedative Agents
article

Processed EEG Artifacts and Pitfalls: A Narrative Review and a Troubleshooting Mnemonic

Vasyl Katerenchuk, Alexandre Calçada, Ana Correia Batista, Rita Regufe, Alexandre Pinheiro, Irene Ferreira
article en

Abstract

Processed electroencephalography (EEG) is widely used for depth of anesthesia monitoring. However, multiple interference sources can distort raw EEG data, leading to misinterpretation of quantitative EEG (qEEG) indices, potentially resulting in insufficient or excessive depth of anesthesia or burst suppression. This review summarizes qEEG interference and artifact sources, as well as some paradoxical effects and pitfalls, reported in the literature. These factors can be categorized into pharmacological, electromagnetic and mechanical, pathophysiological, and model-related sources. When unexpected qEEG values lack an immediately apparent explanation, a structured approach can be valuable, particularly in complex circumstances. We provide a relatable mnemonic "ANESTHESIA" for troubleshooting potential interference sources. If artifact removal is impractical, this should be acknowledged when adjusting the anesthetic management plan. A systematic approach to identify qEEG artifacts and acknowledge potential pitfalls may improve the reliability of depth of anesthesia monitoring, ultimately enhancing patient safety.

CureusVol. 18(2)
Administração Regional de Saúde de Lisboa e Vale do Tejo (PT)
Openalex Percentile: Top 53%
Anesthesia and Sedative Agents
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.