Static Assessment of Hybrid Double‐Lap Bolted Joints With Additively Manufactured 316L Plates

ABSTRACT The present study examines the static response and evaluates the accuracy of design standards and selected literature‐based design criteria in estimating the load capacity of the inner plates of double‐lap shear bolted connections in single‐ and double‐bolt configurations. The analysis is based on 70 experiments previously reported by the authors, including conventional and additively manufactured inner plates produced by wire arc additive manufacturing and selective laser melting. While additively manufactured plates exhibited load capacities comparable to conventional plates, they generally showed reduced ductility. Experimental load capacities are compared against the European standards EC3‐1‐8 and EC3‐1‐4 and the American standard AISC 370. Although originally developed for carbon steel, EC3‐1‐8 provided the most accurate estimations, whereas EC3‐1‐4 and AISC 370 consistently overestimated the load capacity. Literature‐based equations showed the closest agreement, highlighting limitations in current standards for additively manufactured bolted plates.

Authors

Institutions

Publication Details

Journal
Fatigue & Fracture of Engineering Materials & Structures
Published
2026-02-15
DOI
https://doi.org/10.1111/ffe.70218
Primary Topic
Engineering Structural Analysis Methods
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Static Assessment of Hybrid Double‐Lap Bolted Joints With Additively Manufactured 316L Plates

Giacomo Torelli, Hasan Almuhanna, Luca Susmel
Fatigue & Fracture of Engineering Materials & Structures
Engineering Structural Analysis Methods
article

Static Assessment of Hybrid Double‐Lap Bolted Joints With Additively Manufactured 316L Plates

Giacomo Torelli, Hasan Almuhanna, Luca Susmel
article en

Abstract

ABSTRACT The present study examines the static response and evaluates the accuracy of design standards and selected literature‐based design criteria in estimating the load capacity of the inner plates of double‐lap shear bolted connections in single‐ and double‐bolt configurations. The analysis is based on 70 experiments previously reported by the authors, including conventional and additively manufactured inner plates produced by wire arc additive manufacturing and selective laser melting. While additively manufactured plates exhibited load capacities comparable to conventional plates, they generally showed reduced ductility. Experimental load capacities are compared against the European standards EC3‐1‐8 and EC3‐1‐4 and the American standard AISC 370. Although originally developed for carbon steel, EC3‐1‐8 provided the most accurate estimations, whereas EC3‐1‐4 and AISC 370 consistently overestimated the load capacity. Literature‐based equations showed the closest agreement, highlighting limitations in current standards for additively manufactured bolted plates.

Fatigue & Fracture of Engineering Materials & Structures
Sheffield Hallam University (GB), University of Sheffield (GB)
Henry Royce Institute, Kuwait Institute for Scientific Research, Engineering and Physical Sciences Research Council
Openalex Percentile: Top 55%
Engineering Structural Analysis Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.