Novel Stochastic Sensors Based on Phthalocyanine Complexes for the Detection of C-NP, IL-6, and CRP in Cardiovascular Diseases

The severity of cardiovascular disease is linked to C-reactive protein, interleukin 6, and C-type natriuretic peptide levels, stressing the need for a sensitive sensor that can detect these biomarkers at ultralow levels in real time. Whole blood samples from confirmed cardiovascular patients were analyzed for C-type natriuretic peptide, C-reactive protein, and interleukin 6 using three stochastic sensors. These sensors were designed using carbon paste matrices decorated with Ag nanoparticles (AgNPs), on which different phthalocyanines were physically immobilized. The sensors exhibited exceptionally low detection limits (1 × 10<sup>-21</sup> g mL<sup>-1</sup>) and broad linear concentration ranges (1 × 10<sup>-21</sup> to 1 × 10<sup>-6</sup> g mL<sup>-1</sup>). The analysis conducted using the Student <i>t</i>-test indicated that there is no statistically significant difference between the results obtained from the three stochastic sensors used in the screening tests of whole blood, with ELISA at a confidence level of 99%.

Authors

Institutions

Publication Details

Journal
Life
Published
2026-02-15
DOI
https://doi.org/10.3390/life16020339
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel Stochastic Sensors Based on Phthalocyanine Complexes for the Detection of C-NP, IL-6, and CRP in Cardiovascular Diseases

Raluca-Ioana Stefan-van Staden, Ruxandra-Maria Ilie-Mihai
Life
Electrochemical sensors and biosensors
article

Novel Stochastic Sensors Based on Phthalocyanine Complexes for the Detection of C-NP, IL-6, and CRP in Cardiovascular Diseases

Raluca-Ioana Stefan-van Staden, Ruxandra-Maria Ilie-Mihai
article en

Abstract

The severity of cardiovascular disease is linked to C-reactive protein, interleukin 6, and C-type natriuretic peptide levels, stressing the need for a sensitive sensor that can detect these biomarkers at ultralow levels in real time. Whole blood samples from confirmed cardiovascular patients were analyzed for C-type natriuretic peptide, C-reactive protein, and interleukin 6 using three stochastic sensors. These sensors were designed using carbon paste matrices decorated with Ag nanoparticles (AgNPs), on which different phthalocyanines were physically immobilized. The sensors exhibited exceptionally low detection limits (1 × 10<sup>-21</sup> g mL<sup>-1</sup>) and broad linear concentration ranges (1 × 10<sup>-21</sup> to 1 × 10<sup>-6</sup> g mL<sup>-1</sup>). The analysis conducted using the Student <i>t</i>-test indicated that there is no statistically significant difference between the results obtained from the three stochastic sensors used in the screening tests of whole blood, with ELISA at a confidence level of 99%.

LifeVol. 16(2)
National Institute of Research and Development for Electrochemistry and Condensed (RO)
Openalex Percentile: Top 55%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.