Bias-Optimized Hydrogen Sensing in a Mo-Electrode Pd/SnO2 Thin-Film Sensor with Integrated Microheater

Hydrogen is a key energy carrier for fuel cell vehicles and hydrogen energy systems. However, its colorless and odorless nature, combined with a wide flammability range, poses significant safety risks in the event of leakage. Accordingly, compact and reliable hydrogen sensors capable of low-ppm detection at moderate operating temperatures are essential for early-stage safety monitoring. In this study, a bias-optimized hydrogen gas sensor based on a Pd-functionalized SnO<sub>2</sub> thin film with Mo electrodes and an integrated microheater is designed, fabricated, and systematically characterized. The sensor employs a Mo-based vertical microheater and a multilayer thermal insulation stack, enabling thermally efficient and stable operation at 250-280 °C with low power consumption. The electrical and sensing properties of the SnO<sub>2</sub> layer are optimized by controlling the oxygen partial pressure during reactive sputtering and post-deposition annealing. The Pd catalytic layer promotes hydrogen dissociation and spillover, resulting in pronounced resistance modulation through surface redox reactions and interfacial charge transport effects. By systematically optimizing the sensing bias voltage, a clear trade-off between sensitivity enhancement and electrical noise is identified, which allows stable and repeatable operation in the low-ppm regime. The sensor response follows a power-law dependence on hydrogen concentration, and an automated measurement platform is employed to evaluate repeatability and statistical performance. Based on baseline noise analysis and concentration-dependent resistance variation, a limit of detection of approximately 6.4 ppm is achieved. Furthermore, a concentration-normalized figure of merit that combines response magnitude and concentration dependence is introduced to quantitatively assess low-concentration hydrogen sensing performance. These results demonstrate that the proposed Mo-electrode Pd/SnO<sub>2</sub> thin-film sensor, enabled by bias-optimized operation and integrated thermal control, provides a robust and scalable platform for safety-critical hydrogen leak detection.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-02-14
DOI
https://doi.org/10.3390/s26041262
Primary Topic
Gas Sensing Nanomaterials and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bias-Optimized Hydrogen Sensing in a Mo-Electrode Pd/SnO2 Thin-Film Sensor with Integrated Microheater

Yong-Kweon Kim, Dong-Chul Park
Sensors
Gas Sensing Nanomaterials and Sensors
article

Bias-Optimized Hydrogen Sensing in a Mo-Electrode Pd/SnO2 Thin-Film Sensor with Integrated Microheater

Yong-Kweon Kim, Dong-Chul Park
article en

Abstract

Hydrogen is a key energy carrier for fuel cell vehicles and hydrogen energy systems. However, its colorless and odorless nature, combined with a wide flammability range, poses significant safety risks in the event of leakage. Accordingly, compact and reliable hydrogen sensors capable of low-ppm detection at moderate operating temperatures are essential for early-stage safety monitoring. In this study, a bias-optimized hydrogen gas sensor based on a Pd-functionalized SnO<sub>2</sub> thin film with Mo electrodes and an integrated microheater is designed, fabricated, and systematically characterized. The sensor employs a Mo-based vertical microheater and a multilayer thermal insulation stack, enabling thermally efficient and stable operation at 250-280 °C with low power consumption. The electrical and sensing properties of the SnO<sub>2</sub> layer are optimized by controlling the oxygen partial pressure during reactive sputtering and post-deposition annealing. The Pd catalytic layer promotes hydrogen dissociation and spillover, resulting in pronounced resistance modulation through surface redox reactions and interfacial charge transport effects. By systematically optimizing the sensing bias voltage, a clear trade-off between sensitivity enhancement and electrical noise is identified, which allows stable and repeatable operation in the low-ppm regime. The sensor response follows a power-law dependence on hydrogen concentration, and an automated measurement platform is employed to evaluate repeatability and statistical performance. Based on baseline noise analysis and concentration-dependent resistance variation, a limit of detection of approximately 6.4 ppm is achieved. Furthermore, a concentration-normalized figure of merit that combines response magnitude and concentration dependence is introduced to quantitatively assess low-concentration hydrogen sensing performance. These results demonstrate that the proposed Mo-electrode Pd/SnO<sub>2</sub> thin-film sensor, enabled by bias-optimized operation and integrated thermal control, provides a robust and scalable platform for safety-critical hydrogen leak detection.

SensorsVol. 26(4)
Dongyang Mirae University (KR), Seoul National University (KR)
Affordable and clean energy
Openalex Percentile: Top 55%
Gas Sensing Nanomaterials and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.