Material-Specific Surface Degradation of Pediatric Dental Restorations Following Iron Supplement Exposure: An In-Vitro Study

Introduction This study aimed to evaluate the material-specific effects of pediatric iron supplement exposure on the surface roughness of commonly used restorative materials. Methods In this in vitro study, two pediatric iron formulations, Ferrum® and Ferro Sanol® B, were tested on four restorative materials: composite resin, compomer, flowable composite, and glass ionomer cement (GIC). A total of 180 cylindrical specimens (5 × 3 mm) were prepared and allocated into twelve subgroups (n = 15). Specimens were immersed daily for two minutes in the assigned solutions and stored in distilled water between exposures. Surface roughness (Ra, μm) was measured at baseline, day one, day seven, and day 28 using a contact profilometer. Data were analyzed using repeated measures analysis of variance (ANOVA) with Bonferroni and Tukey post hoc tests (p < 0.05). Results All restorative materials showed significant time-dependent increases in surface roughness (p < 0.001). At day 28, glass ionomer cement exhibited the highest Ra values under all conditions (control: 4.03 ± 0.97 μm; Ferrum®: 5.24 ± 0.99 μm; Ferro Sanol® B: 5.95 ± 1.82 μm). Resin-based materials demonstrated lower but significant roughness increases, with composite resin, compomer, and flowable composite showing greater Ra values after iron supplement exposure compared with controls (p < 0.05). Ferro Sanol® B generally induced higher roughness than Ferrum® at later time points, particularly in resin-based materials. Conclusion Exposure to pediatric iron supplements results in material-specific surface degradation of restorative materials. GIC is the most susceptible, while resin-based materials exhibit greater resistance, highlighting the importance of careful material selection in pediatric patients undergoing long-term iron supplementation.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2026-02-14
DOI
https://doi.org/10.7759/cureus.103627
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Material-Specific Surface Degradation of Pediatric Dental Restorations Following Iron Supplement Exposure: An In-Vitro Study

Hülya Çerçi Akçay, Selen Bozkaya Bilgin, Çağan Taş, Eda Sir et al.
Cureus
Dental materials and restorations
article

Material-Specific Surface Degradation of Pediatric Dental Restorations Following Iron Supplement Exposure: An In-Vitro Study

Hülya Çerçi Akçay, Selen Bozkaya Bilgin, Çağan Taş, Eda Sir, Kubra Kavram Sarihan
article en

Abstract

Introduction This study aimed to evaluate the material-specific effects of pediatric iron supplement exposure on the surface roughness of commonly used restorative materials. Methods In this in vitro study, two pediatric iron formulations, Ferrum® and Ferro Sanol® B, were tested on four restorative materials: composite resin, compomer, flowable composite, and glass ionomer cement (GIC). A total of 180 cylindrical specimens (5 × 3 mm) were prepared and allocated into twelve subgroups (n = 15). Specimens were immersed daily for two minutes in the assigned solutions and stored in distilled water between exposures. Surface roughness (Ra, μm) was measured at baseline, day one, day seven, and day 28 using a contact profilometer. Data were analyzed using repeated measures analysis of variance (ANOVA) with Bonferroni and Tukey post hoc tests (p < 0.05). Results All restorative materials showed significant time-dependent increases in surface roughness (p < 0.001). At day 28, glass ionomer cement exhibited the highest Ra values under all conditions (control: 4.03 ± 0.97 μm; Ferrum®: 5.24 ± 0.99 μm; Ferro Sanol® B: 5.95 ± 1.82 μm). Resin-based materials demonstrated lower but significant roughness increases, with composite resin, compomer, and flowable composite showing greater Ra values after iron supplement exposure compared with controls (p < 0.05). Ferro Sanol® B generally induced higher roughness than Ferrum® at later time points, particularly in resin-based materials. Conclusion Exposure to pediatric iron supplements results in material-specific surface degradation of restorative materials. GIC is the most susceptible, while resin-based materials exhibit greater resistance, highlighting the importance of careful material selection in pediatric patients undergoing long-term iron supplementation.

CureusVol. 18(2)
Kocaeli Üniversitesi (TR)
Openalex Percentile: Top 55%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Material-Specific Surface Degradation of Pediatric Dental Restorations Following Iron Supplement Exposure: An In-Vitro Study — Hülya Çerçi Akçay, Selen Bozkaya Bilgin, et al. · Cureus (2026) | TGRS Research Map | TGRS