Preliminary Evaluation of a High-Class Treatment Dental Implant Surface: A TOF-SIMS Study

Background: Surface chemistry and cleanliness are widely regarded as important factors influencing the host response to titanium dental implants. Despite advances in manufacturing and sterilization, trace residues may persist at the nanoscale even in commercially sterile devices. This study provides a preliminary evaluation of premium-grade titanium dental implants using time-of-flight secondary ion mass spectrometry (ToF-SIMS) to assess surface chemical uniformity and trace contaminant distribution. Method: Two commercially available titanium implants from Schütz Dental were analyzed under static and dynamic ToF-SIMS modes using Bi3+ and Cs+ ion beams. Both positive and negative ion spectra were collected to identify elemental and molecular species. Chemical mapping and depth profiling were performed to evaluate contaminant distribution and surface depth composition. Results: In the two implants analyzed, the surfaces were dominated by TiO+ and TiO2+ species, consistent with a native titanium oxide layer. In both analyzed implants, localized contaminants—including fluorine, chlorine, sulfur, CN groups, and organic residues—were detected within the outermost ~0.1 µm. These signals showed heterogeneous distribution along the thread-related regions within the analyzed ROIs, compatible with residues originating from machining, surface treatments, packaging, and/or sterilization steps. Conclusions: The present data support only the descriptive finding that trace contaminants were detected on the two analyzed implants. ToF-SIMS enabled nanoscale chemical mapping and depth profiling of these residues, supporting the feasibility of this approach for trace-level surface auditing and hypothesis generation. Any biological/clinical implications remain speculative and require dedicated in vitro/in vivo validation on larger sample sets.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-02-14
DOI
https://doi.org/10.3390/app16041936
Primary Topic
Ion-surface interactions and analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preliminary Evaluation of a High-Class Treatment Dental Implant Surface: A TOF-SIMS Study

Salvatore Bocchieri, Antonino Licciardello, Pierluigi Mariani, Marco Cicciù et al.
Applied Sciences
Ion-surface interactions and analysis
article

Preliminary Evaluation of a High-Class Treatment Dental Implant Surface: A TOF-SIMS Study

Salvatore Bocchieri, Antonino Licciardello, Pierluigi Mariani, Marco Cicciù, Cesare D’Amico, Gabriele Cervino, Vincenzo Ronsivalle
article en

Abstract

Background: Surface chemistry and cleanliness are widely regarded as important factors influencing the host response to titanium dental implants. Despite advances in manufacturing and sterilization, trace residues may persist at the nanoscale even in commercially sterile devices. This study provides a preliminary evaluation of premium-grade titanium dental implants using time-of-flight secondary ion mass spectrometry (ToF-SIMS) to assess surface chemical uniformity and trace contaminant distribution. Method: Two commercially available titanium implants from Schütz Dental were analyzed under static and dynamic ToF-SIMS modes using Bi3+ and Cs+ ion beams. Both positive and negative ion spectra were collected to identify elemental and molecular species. Chemical mapping and depth profiling were performed to evaluate contaminant distribution and surface depth composition. Results: In the two implants analyzed, the surfaces were dominated by TiO+ and TiO2+ species, consistent with a native titanium oxide layer. In both analyzed implants, localized contaminants—including fluorine, chlorine, sulfur, CN groups, and organic residues—were detected within the outermost ~0.1 µm. These signals showed heterogeneous distribution along the thread-related regions within the analyzed ROIs, compatible with residues originating from machining, surface treatments, packaging, and/or sterilization steps. Conclusions: The present data support only the descriptive finding that trace contaminants were detected on the two analyzed implants. ToF-SIMS enabled nanoscale chemical mapping and depth profiling of these residues, supporting the feasibility of this approach for trace-level surface auditing and hypothesis generation. Any biological/clinical implications remain speculative and require dedicated in vitro/in vivo validation on larger sample sets.

Applied SciencesVol. 16(4)
University of Messina (IT), University of Campania "Luigi Vanvitelli" (IT), University of Catania (IT)
Industry, innovation and infrastructure
Openalex Percentile: Top 51%
Ion-surface interactions and analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.