High-Efficiency Arsenic Removal from Water Using Electrocoagulation: Experimental Study and Process Optimization

Abstract: Arsenic contamination in groundwater poses a major health threat globally, particularly in South and Southeast Asia, where millions rely on arsenic-laden water sources. This study investigates the effectiveness of electrocoagulation (EC) as a treatment method for arsenic removal, emphasizing its operational simplicity and cost-efficiency. The main objective was to evaluate arsenic removal efficiency using EC with aluminum and iron electrodes under varying conditions and to identify optimal operational parameters through experimental design. Synthetic wastewater samples with arsenic concentrations of 100 ppb and 300 ppb were treated under different pH levels, current densities, and reaction times. A Box–Behnken design within the response surface methodology (RSM) framework was employed to systematically explore parameter interactions. The results showed that at 100 ppb, arsenic removal efficiency reached 99.2% under optimal conditions of pH 7.0, current density 25 A/m², and reaction time 40 minutes. For the 300ppb concentration, maximum removal efficiency was slightly lower at 96.73% under similar optimized conditions. Statistical modeling confirmed strong predictive accuracy for the 100ppb scenario (R² = 0.997), while a slightly reduced fit was observed for the 300ppb case (R² = 0.980). The findings demonstrate the viability of EC as an efficient, scalable treatment for arsenic-contaminated water, with optimal performance at neutral pH and moderate current densities. This research provides valuable insight into designing decentralized water treatment systems, particularly in resource-constrained settings, and supports EC as a promising technology for mitigating arsenic exposure in vulnerable communities.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-02-15
DOI
https://doi.org/10.5281/zenodo.18648177
Primary Topic
Advanced oxidation water treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Efficiency Arsenic Removal from Water Using Electrocoagulation: Experimental Study and Process Optimization

Le Phu Tuan1*, Vaiyakone Patoumphone2, Florencio C. Ballesteros3, Tran Quoc Tuan4, Nguyen Thanh Vinh5, Tien Van Manh6, Tran Khoa Dang7
Zenodo (CERN European Organization for Nuclear Research)
Advanced oxidation water treatment
article

High-Efficiency Arsenic Removal from Water Using Electrocoagulation: Experimental Study and Process Optimization

Le Phu Tuan1*, Vaiyakone Patoumphone2, Florencio C. Ballesteros3, Tran Quoc Tuan4, Nguyen Thanh Vinh5, Tien Van Manh6, Tran Khoa Dang7
article en

Abstract

Abstract: Arsenic contamination in groundwater poses a major health threat globally, particularly in South and Southeast Asia, where millions rely on arsenic-laden water sources. This study investigates the effectiveness of electrocoagulation (EC) as a treatment method for arsenic removal, emphasizing its operational simplicity and cost-efficiency. The main objective was to evaluate arsenic removal efficiency using EC with aluminum and iron electrodes under varying conditions and to identify optimal operational parameters through experimental design. Synthetic wastewater samples with arsenic concentrations of 100 ppb and 300 ppb were treated under different pH levels, current densities, and reaction times. A Box–Behnken design within the response surface methodology (RSM) framework was employed to systematically explore parameter interactions. The results showed that at 100 ppb, arsenic removal efficiency reached 99.2% under optimal conditions of pH 7.0, current density 25 A/m², and reaction time 40 minutes. For the 300ppb concentration, maximum removal efficiency was slightly lower at 96.73% under similar optimized conditions. Statistical modeling confirmed strong predictive accuracy for the 100ppb scenario (R² = 0.997), while a slightly reduced fit was observed for the 300ppb case (R² = 0.980). The findings demonstrate the viability of EC as an efficient, scalable treatment for arsenic-contaminated water, with optimal performance at neutral pH and moderate current densities. This research provides valuable insight into designing decentralized water treatment systems, particularly in resource-constrained settings, and supports EC as a promising technology for mitigating arsenic exposure in vulnerable communities.

Zenodo (CERN European Organization for Nuclear Research)
University Of Transport Technology (VN)
Clean water and sanitation
Openalex Percentile: Top 58%
Advanced oxidation water treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.