A Thermoresponsive, Electrically Conductive Bioink Optimized for Electroactive Tissue Engineering and Bioelectronics

Achieving thermoresponsive behavior, electrical conductivity, printability, and biocompatibility within a single bioink formulation remains a significant challenge, yet this combination is essential for creating stable, electroactive 3D constructs that function under physiologically relevant conditions. To address this unmet need, this study aimed to develop a thermoresponsive and electrically conductive bioink through the systematic formulation and evaluation of 12 hydrogels composed of agarose, gelatin, HPC, and PEDOT:PSS. Among these, a formulation comprising 2% w/w agarose, 4% w/w gelatin, 2% w/w HPC, and 0.1% PEDOT:PSS exhibited the most balanced performance, demonstrating favorable shear-thinning rheology, high print fidelity, structural stability, and high electrical conductivity (0.5757 S/m). Comprehensive biological assays confirmed no significant changes in A549 cell viability across different embedding conditions, while SEM imaging of 3D-printed structures revealed micro- to mesoscale pores suitable for cell infiltration and small molecule transport. Critically, optimizing the PEDOT:PSS content enabled effective conductivity without compromising mechanical properties or biocompatibility. The systematic design approach demonstrated herein provides a reproducible framework for creating multifunctional conductive bioinks that successfully balance thermoresponsive behavior, printability, electrical conductivity, and biocompatibility in a single material. By integration of all essential functional properties into a single formulation, these findings advance the development of application-ready bioinks. The resulting printed structures can be used immediately, without any postprinting modification or functionalization, thereby supporting rapid translation into tissue engineering, biosensing, and bioelectronic applications.

Authors

Institutions

Publication Details

Journal
ACS Applied Bio Materials
Published
2026-02-15
DOI
https://doi.org/10.1021/acsabm.5c02097
Primary Topic
3D Printing in Biomedical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Thermoresponsive, Electrically Conductive Bioink Optimized for Electroactive Tissue Engineering and Bioelectronics

Nicholas Dunne, Loanda R. Cumba, Keith D. Rochfort, John Redmond et al.
ACS Applied Bio Materials
3D Printing in Biomedical Research
article

A Thermoresponsive, Electrically Conductive Bioink Optimized for Electroactive Tissue Engineering and Bioelectronics

Nicholas Dunne, Loanda R. Cumba, Keith D. Rochfort, John Redmond, Amanda Carrico, Róisín Byrne, Robert J Forster
article en

Abstract

Achieving thermoresponsive behavior, electrical conductivity, printability, and biocompatibility within a single bioink formulation remains a significant challenge, yet this combination is essential for creating stable, electroactive 3D constructs that function under physiologically relevant conditions. To address this unmet need, this study aimed to develop a thermoresponsive and electrically conductive bioink through the systematic formulation and evaluation of 12 hydrogels composed of agarose, gelatin, HPC, and PEDOT:PSS. Among these, a formulation comprising 2% w/w agarose, 4% w/w gelatin, 2% w/w HPC, and 0.1% PEDOT:PSS exhibited the most balanced performance, demonstrating favorable shear-thinning rheology, high print fidelity, structural stability, and high electrical conductivity (0.5757 S/m). Comprehensive biological assays confirmed no significant changes in A549 cell viability across different embedding conditions, while SEM imaging of 3D-printed structures revealed micro- to mesoscale pores suitable for cell infiltration and small molecule transport. Critically, optimizing the PEDOT:PSS content enabled effective conductivity without compromising mechanical properties or biocompatibility. The systematic design approach demonstrated herein provides a reproducible framework for creating multifunctional conductive bioinks that successfully balance thermoresponsive behavior, printability, electrical conductivity, and biocompatibility in a single material. By integration of all essential functional properties into a single formulation, these findings advance the development of application-ready bioinks. The resulting printed structures can be used immediately, without any postprinting modification or functionalization, thereby supporting rapid translation into tissue engineering, biosensing, and bioelectronic applications.

ACS Applied Bio MaterialsVol. 9(6)
Queen's University Belfast (GB), Royal College of Surgeons in Ireland (IE), Centre for Biomedical Engineering and Physics (SE), Advanced Materials and BioEngineering Research (IE), Biodesigns (United States) (US), I-Form Advanced Manufacturing Research Centre (IE), Dublin City University (IE)
Openalex Percentile: Top 56%
3D Printing in Biomedical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.