Peak-Independent Cuffless Blood Pressure Monitoring Using a Smart Sock: The Role of Temporal Lag Modeling in Foot-Based PPG

Continuous blood pressure (BP) monitoring remains a major challenge in wearable healthcare systems, as conventional cuff-based sphygmomanometers are intermittent and unsuitable for long-term use. This study presents a Smart Sock platform for cuffless BP estimation using single-site photoplethysmography (PPG). Unlike approaches based on pulse transit time or fiducial point detection, the proposed framework relies on peak-independent features extracted from PPG and its first and second derivatives, capturing blood volume and hemodynamic dynamics in the lower limb. PPG signals from 60 participants were segmented into overlapping 30 s windows and processed through a unified preprocessing pipeline. A compact set of physiologically meaningful statistical and information-theoretic features was extracted from each window, and temporal lag modelling (5-15 s) was employed to encode short-term hemodynamic memory without explicit peak detection. Multiple regression models were assessed using leakage-safe cross-validation strategies. In a subject-independent diagnosis scenario, the system achieved errors of 8.60 mmHg for systolic BP and 6.42 mmHg for diastolic BP. In a monitoring scenario with single-point calibration, performance substantially improved, yielding mean absolute errors of 1.3-1.7 mmHg and R<sup>2</sup> > 0.90. These results demonstrate that foot-based PPG, combined with peak-independent feature engineering and temporal context modeling, enables accurate and comfortable continuous personalized blood pressure monitoring after calibration, while subject-independent estimation remains more challenging.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-02-15
DOI
https://doi.org/10.3390/s26041269
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Peak-Independent Cuffless Blood Pressure Monitoring Using a Smart Sock: The Role of Temporal Lag Modeling in Foot-Based PPG

Riccardo Olivieri, Vincenzo Stornelli, Giuseppe Ferri, Gianluca Barile et al.
Sensors
Non-Invasive Vital Sign Monitoring
article

Peak-Independent Cuffless Blood Pressure Monitoring Using a Smart Sock: The Role of Temporal Lag Modeling in Foot-Based PPG

Riccardo Olivieri, Vincenzo Stornelli, Giuseppe Ferri, Gianluca Barile, Hamed Abdollahzadeh, Paolo Esposito, Elisa Montaldi
article en

Abstract

Continuous blood pressure (BP) monitoring remains a major challenge in wearable healthcare systems, as conventional cuff-based sphygmomanometers are intermittent and unsuitable for long-term use. This study presents a Smart Sock platform for cuffless BP estimation using single-site photoplethysmography (PPG). Unlike approaches based on pulse transit time or fiducial point detection, the proposed framework relies on peak-independent features extracted from PPG and its first and second derivatives, capturing blood volume and hemodynamic dynamics in the lower limb. PPG signals from 60 participants were segmented into overlapping 30 s windows and processed through a unified preprocessing pipeline. A compact set of physiologically meaningful statistical and information-theoretic features was extracted from each window, and temporal lag modelling (5-15 s) was employed to encode short-term hemodynamic memory without explicit peak detection. Multiple regression models were assessed using leakage-safe cross-validation strategies. In a subject-independent diagnosis scenario, the system achieved errors of 8.60 mmHg for systolic BP and 6.42 mmHg for diastolic BP. In a monitoring scenario with single-point calibration, performance substantially improved, yielding mean absolute errors of 1.3-1.7 mmHg and R<sup>2</sup> > 0.90. These results demonstrate that foot-based PPG, combined with peak-independent feature engineering and temporal context modeling, enables accurate and comfortable continuous personalized blood pressure monitoring after calibration, while subject-independent estimation remains more challenging.

SensorsVol. 26(4)
University of L'Aquila (IT)
Good health and well-being
Openalex Percentile: Top 56%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Peak-Independent Cuffless Blood Pressure Monitoring Using a Smart Sock: The Role of Temporal Lag Modeling in Foot-Based PPG — Riccardo Olivieri, Vincenzo Stornelli, et al. · Sensors (2026) | TGRS Research Map | TGRS