Structural Features of Nerve Guidance Conduits and Scaffolds in Preventing Axonal Misdirection: A Systematic Review of Retrograde Tracing Studies

<b>Background:</b> Axonal misdirection remains a major limitation in peripheral nerve repair. While nerve guidance conduits (NGCs) and nerve scaffolds (NSCs) have advanced structurally, it is unclear whether these designs effectively reduce misdirection compared to autografts (ANGs). This systematic review evaluates the impact of NGC and NSC structural features on axonal dispersion and reinnervation accuracy using retrograde tracing animal models. <b>Methods:</b> A systematic search was performed through Medline (PubMed), Scopus (EBSCOhost), and the Cochrane Library from inception to December 2024. Eligible studies included mammalian in vivo models of peripheral nerve transection repaired by direct coaptation, autografts, or artificial conduits and assessed with retrograde axonal tracing. Data on neurons labeling, innervation accuracy, and histomorphometric parameters were extracted, and misdirection rates were calculated. Risk of bias was assessed using the SYRCLE tool. Due to heterogeneity, data were synthesized narratively following the SWiM framework. <b>Results:</b> Out of 4043 records identified through database searching and 37 through citation searching, 19 studies (49 experimental groups) met the inclusion criteria. Motoneuron counts were consistently reported across all arms, but no outcome assessing axonal misdirection was reported in more than half. Structured designs resulted in outcomes more closely aligned with ANG repair, while unstructured generally underperformed, and certainty of evidence was very low. <b>Discussion:</b> The evidence in this study was limited by high risk of bias, substantial inconsistency across heterogeneous study designs and outcomes, and imprecision from small animal models with sparse outcome measures. Despite the trend for structured designs to improve over basic hollow designs, current evidence does not support any structure as superior. Future research should be more standardized to provide reliable knowledge translational into clinical practice.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2026-02-13
DOI
https://doi.org/10.3390/bioengineering13020220
Primary Topic
Nerve injury and regeneration
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Structural Features of Nerve Guidance Conduits and Scaffolds in Preventing Axonal Misdirection: A Systematic Review of Retrograde Tracing Studies

Milan Lepić, Aleksa Mićić, Jovan Grujić, Joko Poleksić et al.
Bioengineering
Nerve injury and regeneration
article

Structural Features of Nerve Guidance Conduits and Scaffolds in Preventing Axonal Misdirection: A Systematic Review of Retrograde Tracing Studies

Milan Lepić, Aleksa Mićić, Jovan Grujić, Joko Poleksić, Dubravka Aleksić, Andrija Savić, Milan Aksić, Lazar Vujić, Lukas Rasulić
article en

Abstract

<b>Background:</b> Axonal misdirection remains a major limitation in peripheral nerve repair. While nerve guidance conduits (NGCs) and nerve scaffolds (NSCs) have advanced structurally, it is unclear whether these designs effectively reduce misdirection compared to autografts (ANGs). This systematic review evaluates the impact of NGC and NSC structural features on axonal dispersion and reinnervation accuracy using retrograde tracing animal models. <b>Methods:</b> A systematic search was performed through Medline (PubMed), Scopus (EBSCOhost), and the Cochrane Library from inception to December 2024. Eligible studies included mammalian in vivo models of peripheral nerve transection repaired by direct coaptation, autografts, or artificial conduits and assessed with retrograde axonal tracing. Data on neurons labeling, innervation accuracy, and histomorphometric parameters were extracted, and misdirection rates were calculated. Risk of bias was assessed using the SYRCLE tool. Due to heterogeneity, data were synthesized narratively following the SWiM framework. <b>Results:</b> Out of 4043 records identified through database searching and 37 through citation searching, 19 studies (49 experimental groups) met the inclusion criteria. Motoneuron counts were consistently reported across all arms, but no outcome assessing axonal misdirection was reported in more than half. Structured designs resulted in outcomes more closely aligned with ANG repair, while unstructured generally underperformed, and certainty of evidence was very low. <b>Discussion:</b> The evidence in this study was limited by high risk of bias, substantial inconsistency across heterogeneous study designs and outcomes, and imprecision from small animal models with sparse outcome measures. Despite the trend for structured designs to improve over basic hollow designs, current evidence does not support any structure as superior. Future research should be more standardized to provide reliable knowledge translational into clinical practice.

BioengineeringVol. 13(2)
Military Medical Academy (RS), University of Belgrade (RS), University Clinical Centre (PL), University of Defence (RS)
Openalex Percentile: Top 57%
Nerve injury and regeneration
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.