De-aberration for noninvasive transcranial photoacoustic computed tomography through an adult human skull

Abstract Noninvasive transcranial photoacoustic computed tomography (PACT) of the human brain, despite its clinical potential as a complementary technology to functional MRI, remains impeded by the acoustic distortion induced by the human skull. The distortion, which is attributed to the markedly different material properties of the skull relative to soft tissue, results in heavily aberrated PACT images. Herein, we report an experimental demonstration of the de-aberration of PACT images through an ex-vivo adult human skull using a homogeneous elastic model for the skull. Using only the geometry, position, and orientation of the skull, obtained from adjunct imaging data and fiducial markers, we faithfully de-aberrate the PACT images of light-absorbing phantoms acquired through an ex-vivo human skull for different levels of phantom complexity and positions. We also demonstrate the generality of our results by attaining a similar extent of de-aberration through a second ex-vivo human skull. Our work addresses the longstanding challenge of skull-induced aberrations in transcranial PACT and advances the field towards unlocking the full potential of transcranial human brain PACT.

Authors

Institutions

Publication Details

Journal
Communications Physics
Published
2026-02-14
DOI
https://doi.org/10.1038/s42005-026-02545-3
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

De-aberration for noninvasive transcranial photoacoustic computed tomography through an adult human skull

Manxiu Cui, Yilin Luo, Geng Ku, Jigmi Basumatary et al.
Communications Physics
Photoacoustic and Ultrasonic Imaging
article

De-aberration for noninvasive transcranial photoacoustic computed tomography through an adult human skull

Manxiu Cui, Yilin Luo, Geng Ku, Jigmi Basumatary, Junhao Zhu, Siying Kong, Yang Zhang, Rui Cao, Yousuf Aborahama, Lihong V. Wang, Karteekeya Sastry
article en

Abstract

Abstract Noninvasive transcranial photoacoustic computed tomography (PACT) of the human brain, despite its clinical potential as a complementary technology to functional MRI, remains impeded by the acoustic distortion induced by the human skull. The distortion, which is attributed to the markedly different material properties of the skull relative to soft tissue, results in heavily aberrated PACT images. Herein, we report an experimental demonstration of the de-aberration of PACT images through an ex-vivo adult human skull using a homogeneous elastic model for the skull. Using only the geometry, position, and orientation of the skull, obtained from adjunct imaging data and fiducial markers, we faithfully de-aberrate the PACT images of light-absorbing phantoms acquired through an ex-vivo human skull for different levels of phantom complexity and positions. We also demonstrate the generality of our results by attaining a similar extent of de-aberration through a second ex-vivo human skull. Our work addresses the longstanding challenge of skull-induced aberrations in transcranial PACT and advances the field towards unlocking the full potential of transcranial human brain PACT.

Communications Physics
California Institute of Technology (US)
California Institute of Technology, National Institutes of Health
Openalex Percentile: Top 56%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.