Impact of Needle Bevel Orientation on Hemodynamic Stability and Quality of Spinal Anesthesia for Cesarean Section: A Prospective Randomized Study

Introduction: Maternal arterial hypotension is the most common complication of spinal anesthesia for cesarean section, potentially compromising maternal and fetal safety. The objective of this study was to evaluate whether a simple technical modification, the orientation of the needle bevel, could reduce the incidence of this hypotension.Methods: A prospective, randomized, comparative study was conducted on 100 parturients (ASA I-III) undergoing emergency cesarean section. Patients were divided into two groups: Group I (n=54) received spinal anesthesia with a conventional cephalad bevel orientation, and Group II (n=46) with a caudad orientation. All participants received 10 mg of hyperbaric bupivacaine and 25 mcg of fentanyl. The primary endpoint was the incidence of hypotension (defined as SBP < 100 mmHg or a drop > 20% from baseline).Results: The incidence of hypotension was significantly lower in the caudad orientation group (10.8%) compared to the cephalad orientation group (38.8%, p = 0.039). Ephedrine consumption was reduced by over 70% in the caudad group (3.0 ± 1.8 mg vs 11.9 ± 4.2 mg, p < 0.05). Furthermore, 78.3% of patients in the caudad group required no vasopressors, compared to 37% in the cephalad group (p < 0.05). The sensory block level was lower (T5 vs T3) and had a slower onset (time to T6: 10 vs 6 min) in the caudad group, while remaining clinically effective.Conclusion: Caudad orientation of the needle bevel is a simple, effective, and cost-free technique to improve the safety of obstetric spinal anesthesia. It significantly reduces the incidence of maternal hypotension and vasopressor consumption, at the cost of a slightly slower onset of the anesthetic block.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-02-14
DOI
https://doi.org/10.5281/zenodo.18640258
Primary Topic
Anesthesia and Pain Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Needle Bevel Orientation on Hemodynamic Stability and Quality of Spinal Anesthesia for Cesarean Section: A Prospective Randomized Study

Amine Raja, Amine Afif, Smeal ELYOUSSOUFI, Sais SALMI et al.
Zenodo (CERN European Organization for Nuclear Research)
Anesthesia and Pain Management
article

Impact of Needle Bevel Orientation on Hemodynamic Stability and Quality of Spinal Anesthesia for Cesarean Section: A Prospective Randomized Study

Amine Raja, Amine Afif, Smeal ELYOUSSOUFI, Sais SALMI, Marouan HARRIT, Abdelhamid TAQUI, Maria BENZAKOUR, Ayoub SEHBAOUI
article en

Abstract

Introduction: Maternal arterial hypotension is the most common complication of spinal anesthesia for cesarean section, potentially compromising maternal and fetal safety. The objective of this study was to evaluate whether a simple technical modification, the orientation of the needle bevel, could reduce the incidence of this hypotension.Methods: A prospective, randomized, comparative study was conducted on 100 parturients (ASA I-III) undergoing emergency cesarean section. Patients were divided into two groups: Group I (n=54) received spinal anesthesia with a conventional cephalad bevel orientation, and Group II (n=46) with a caudad orientation. All participants received 10 mg of hyperbaric bupivacaine and 25 mcg of fentanyl. The primary endpoint was the incidence of hypotension (defined as SBP < 100 mmHg or a drop > 20% from baseline).Results: The incidence of hypotension was significantly lower in the caudad orientation group (10.8%) compared to the cephalad orientation group (38.8%, p = 0.039). Ephedrine consumption was reduced by over 70% in the caudad group (3.0 ± 1.8 mg vs 11.9 ± 4.2 mg, p < 0.05). Furthermore, 78.3% of patients in the caudad group required no vasopressors, compared to 37% in the cephalad group (p < 0.05). The sensory block level was lower (T5 vs T3) and had a slower onset (time to T6: 10 vs 6 min) in the caudad group, while remaining clinically effective.Conclusion: Caudad orientation of the needle bevel is a simple, effective, and cost-free technique to improve the safety of obstetric spinal anesthesia. It significantly reduces the incidence of maternal hypotension and vasopressor consumption, at the cost of a slightly slower onset of the anesthetic block.

Zenodo (CERN European Organization for Nuclear Research)
Mother Hospital (IN), University of Hassan II Casablanca (MA)
Good health and well-being
Openalex Percentile: Top 55%
Anesthesia and Pain Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.