Impact of protective coatings on fire resistance and axial capacity of galvanised CFS columns

The literature on the structural performance of cold-formed steel (CFS) columns under fire conditions is limited. This study delivers critical insights into the buckling behaviour of back-to-back connected CFS columns with three different fire-resistant coatings. These columns underwent various heating and cooling procedures. Outcomes of this research offer significant implications for building codes and standards, particularly in understanding the effects of thermal exposure and cooling methods on CFS structural elements. In all specimens, the failure pattern observed was consistent, characterised primarily by significant buckling. Notably, sections coated with perlite demonstrated superior performance in fire resistance compared with other sections that were coated and heated. Among the coated specimens heated to 60 min and cooled using air, BC2AC (perlite) has the highest ultimate load at 268.93 kN, which is just 1.7% lower than the unheated section and 7.2% higher than BC1AC (gypsum) and 12.6% higher than BC3AC (vermiculite). This study contributes essential observations into the axial resistance of columns with various coatings under varying temperature and cooling conditions, potentially informing updates to standard guidelines regarding the impact of heating and cooling.

Authors

Institutions

Publication Details

Journal
Proceedings of the Institution of Civil Engineers - Forensic Engineering
Published
2026-02-14
DOI
https://doi.org/10.1680/jfoen.25.00037
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of protective coatings on fire resistance and axial capacity of galvanised CFS columns

Anand Nammalvar, Varun Sabu Sam, Andrainik Iswarary, MZ Nazer
Proceedings of the Institution of Civil Engineers - Forensic Engineering
Structural Load-Bearing Analysis
article

Impact of protective coatings on fire resistance and axial capacity of galvanised CFS columns

Anand Nammalvar, Varun Sabu Sam, Andrainik Iswarary, MZ Nazer
article en

Abstract

The literature on the structural performance of cold-formed steel (CFS) columns under fire conditions is limited. This study delivers critical insights into the buckling behaviour of back-to-back connected CFS columns with three different fire-resistant coatings. These columns underwent various heating and cooling procedures. Outcomes of this research offer significant implications for building codes and standards, particularly in understanding the effects of thermal exposure and cooling methods on CFS structural elements. In all specimens, the failure pattern observed was consistent, characterised primarily by significant buckling. Notably, sections coated with perlite demonstrated superior performance in fire resistance compared with other sections that were coated and heated. Among the coated specimens heated to 60 min and cooled using air, BC2AC (perlite) has the highest ultimate load at 268.93 kN, which is just 1.7% lower than the unheated section and 7.2% higher than BC1AC (gypsum) and 12.6% higher than BC3AC (vermiculite). This study contributes essential observations into the axial resistance of columns with various coatings under varying temperature and cooling conditions, potentially informing updates to standard guidelines regarding the impact of heating and cooling.

Proceedings of the Institution of Civil Engineers - Forensic Engineering
Karunya University (IN), Clemson University (US)
Sustainable cities and communities
Openalex Percentile: Top 57%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Impact of protective coatings on fire resistance and axial capacity of galvanised CFS columns — Anand Nammalvar, Varun Sabu Sam, et al. · Proceedings of the Institution of Civil Engineers - Forensic Engineering (2026) | TGRS Research Map | TGRS