Design and Real-Time Validation of a Three-Phase Inverter Using an Interleaved Synchronous Super-Lift Luo Converter for Aircraft Power Systems

This paper examines a 24 kVA three-phase inverter supplied by a set of four synchronous Super-Lift Luo DC–DC converters (ISSLLC) connected in parallel to a common DC link. The converters boost a 28 V DC input to approximately 400 V, which then feeds a 115 V, 400 Hz inverter intended for aircraft electrical systems. The overall system was modeled analytically, simulated using PLECS, and validated in real time on a Typhoon HIL platform. In both simulation and HIL, the DC link remained low ripple, and the inverter delivered well-balanced three-phase output voltages. The measured total harmonic distortion was 0.77%, and the power factor was close to unity, staying within MIL-STD-704F limits. The agreement between the simulation and HIL results confirms the precision and real-time feasibility of the proposed ISSLLC-based inverter for aerospace and other high-gain, high-efficiency applications.

Authors

Institutions

Publication Details

Journal
Aerospace
Published
2026-02-14
DOI
https://doi.org/10.3390/aerospace13020185
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Real-Time Validation of a Three-Phase Inverter Using an Interleaved Synchronous Super-Lift Luo Converter for Aircraft Power Systems

Eralp Şener, Gurhan Ertasgin
Aerospace
Advanced DC-DC Converters
article

Design and Real-Time Validation of a Three-Phase Inverter Using an Interleaved Synchronous Super-Lift Luo Converter for Aircraft Power Systems

Eralp Şener, Gurhan Ertasgin
article en

Abstract

This paper examines a 24 kVA three-phase inverter supplied by a set of four synchronous Super-Lift Luo DC–DC converters (ISSLLC) connected in parallel to a common DC link. The converters boost a 28 V DC input to approximately 400 V, which then feeds a 115 V, 400 Hz inverter intended for aircraft electrical systems. The overall system was modeled analytically, simulated using PLECS, and validated in real time on a Typhoon HIL platform. In both simulation and HIL, the DC link remained low ripple, and the inverter delivered well-balanced three-phase output voltages. The measured total harmonic distortion was 0.77%, and the power factor was close to unity, staying within MIL-STD-704F limits. The agreement between the simulation and HIL results confirms the precision and real-time feasibility of the proposed ISSLLC-based inverter for aerospace and other high-gain, high-efficiency applications.

AerospaceVol. 13(2)
Bilecik Şeyh Edebali Üniversitesi (TR)
Affordable and clean energy
Openalex Percentile: Top 55%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.