HS-Carbon v1.0: Energy-Aware Extension for Tick-Canonical Phase-Window Actions (Fixed-Point Fields, HS^E-bit, Carbon-Gated Execution)

HS-Carbon v1.0 is a minimal, optional extension to the Timeverse / Phase-Coordination stack that introduces a deterministic carbon gate for phase-window actions. While Conventions/Q-Address/TAQA define when an action may execute under a cycle-anchored, wrap-safe phase-window convention (tick-canonical), HS-Carbon adds an energy/carbon precondition: an action is eligible to execute only if it is inside the agreed phase window and the local carbon intensity at execution is below a declared threshold. This specification preserves strict separation of concerns: It does not redefine phase/tick semantics (Conventions). It does not redefine execution semantics (Q-Address / TAQA). It does not define cryptography or threat models (Security Profile). It does not replace deterministic policy evaluation (HS-Core); the carbon gate MAY be applied before HS-Core evaluation. Normative contribution Energy-aware window fields (fixed-point integer encodings for enforcement/audit): energy_mwh_u32 (mWh) carbon_threshold_mgco2_per_kwh_u32 (mgCO2/kWh) Deterministic gating semantics producing recommended outcomes: WAIT (out-of-window) and DELAY_CARBON (in-window but carbon too high). HS^E-bit definition: 1 iff (tick-window membership) AND (carbon intensity below threshold). TSAE receipt fields for carbon auditing, including a deterministic fixed-point emissions estimate: estimated_emissions_mgco2_u64 = floor( energy_mwh_u32 * carbon_intensity_mgco2_per_kwh_u32 / 10^6 ). What this record contains HS-Carbon v1.0 PDF specification (normative for HS-Carbon gating semantics only). JSON field examples aligned with a fixed-point reference implementation. Compatibility notes Tick-canonical window membership MUST be evaluated using integer ticks only (no floating-point boundary checks). Energy/carbon fields are public context (not secrets). If external carbon forecasts/certificates are used, authenticity must be verified under deployment trust anchors. Keywords: Timeverse, HS-Carbon, carbon-aware computing, green computing, phase coordination, phase windows, tick-canonical, fixed-point, Q-Address, TAQA, TSAE, HS-Core, HS-Bloch, auditability, deterministic gating, distributed systems, quantum computing.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-02-14
DOI
https://doi.org/10.5281/zenodo.18642026
Primary Topic
Security and Verification in Computing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

HS-Carbon v1.0: Energy-Aware Extension for Tick-Canonical Phase-Window Actions (Fixed-Point Fields, HS^E-bit, Carbon-Gated Execution)

Tarik Ouardi
Zenodo (CERN European Organization for Nuclear Research)
Security and Verification in Computing
article

HS-Carbon v1.0: Energy-Aware Extension for Tick-Canonical Phase-Window Actions (Fixed-Point Fields, HS^E-bit, Carbon-Gated Execution)

Tarik Ouardi
article en

Abstract

HS-Carbon v1.0 is a minimal, optional extension to the Timeverse / Phase-Coordination stack that introduces a deterministic carbon gate for phase-window actions. While Conventions/Q-Address/TAQA define when an action may execute under a cycle-anchored, wrap-safe phase-window convention (tick-canonical), HS-Carbon adds an energy/carbon precondition: an action is eligible to execute only if it is inside the agreed phase window and the local carbon intensity at execution is below a declared threshold. This specification preserves strict separation of concerns: It does not redefine phase/tick semantics (Conventions). It does not redefine execution semantics (Q-Address / TAQA). It does not define cryptography or threat models (Security Profile). It does not replace deterministic policy evaluation (HS-Core); the carbon gate MAY be applied before HS-Core evaluation. Normative contribution Energy-aware window fields (fixed-point integer encodings for enforcement/audit): energy_mwh_u32 (mWh) carbon_threshold_mgco2_per_kwh_u32 (mgCO2/kWh) Deterministic gating semantics producing recommended outcomes: WAIT (out-of-window) and DELAY_CARBON (in-window but carbon too high). HS^E-bit definition: 1 iff (tick-window membership) AND (carbon intensity below threshold). TSAE receipt fields for carbon auditing, including a deterministic fixed-point emissions estimate: estimated_emissions_mgco2_u64 = floor( energy_mwh_u32 * carbon_intensity_mgco2_per_kwh_u32 / 10^6 ). What this record contains HS-Carbon v1.0 PDF specification (normative for HS-Carbon gating semantics only). JSON field examples aligned with a fixed-point reference implementation. Compatibility notes Tick-canonical window membership MUST be evaluated using integer ticks only (no floating-point boundary checks). Energy/carbon fields are public context (not secrets). If external carbon forecasts/certificates are used, authenticity must be verified under deployment trust anchors. Keywords: Timeverse, HS-Carbon, carbon-aware computing, green computing, phase coordination, phase windows, tick-canonical, fixed-point, Q-Address, TAQA, TSAE, HS-Core, HS-Bloch, auditability, deterministic gating, distributed systems, quantum computing.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 57%
Security and Verification in Computing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.