Evaluation of Four 3D Facial Scanning Technologies: From Photogrammetry to Structured-Light Systems in Clinical Dentistry

<b>Background/Objectives:</b> Accurate three-dimensional (3D) facial scanning is increasingly important in digital dentistry for diagnosis, treatment planning, and virtual patient creation. Multiple facial scanning technologies are available; however, their metric reliability varies depending on acquisition principles and anatomical orientation. This study aimed to evaluate the trueness, orientation-dependent performance (vertical midline versus horizontal facial measurements), and scanning time of four facial scanning technologies using calibrated manual anthropometry as the reference standard. <b>Methods:</b> Thirty dentate adult participants received adhesive fiducial markers on five predefined facial landmarks. Four linear facial distances were measured clinically using a digital caliper and compared with corresponding measurements obtained from standardized 3D facial scans. Digital measurements were extracted following uniform metric normalization. Inter-examiner reliability, measurement trueness, orientation-related differences, and scanning time were analyzed. <b>Results:</b> Inter-examiner reliability was excellent for both clinical and digital measurements (ICC > 0.93). All facial scanning technologies significantly overestimated manual distances (<i>p</i> < 0.001). The structured-light scanning system showed the smallest deviations (typically <1 mm) and the highest overall accuracy, followed by the depth-fusion system, while photogrammetry-based and NeRF-based approaches demonstrated larger errors, frequently exceeding 2-3 mm. Horizontal facial distances consistently showed greater deviations than vertical midline measurements across all systems. Scanning time differed significantly between technologies, with passive image-based approaches being the fastest and NeRF-based acquisition requiring the longest capture time. <b>Conclusions:</b> Active structured-light facial scanning demonstrated the highest trueness for linear facial anthropometry, whereas passive photogrammetry and NeRF-based approaches showed lower metric trueness and are currently more suitable for educational applications.

Authors

Institutions

Publication Details

Journal
Dentistry Journal
Published
2026-02-14
DOI
https://doi.org/10.3390/dj14020113
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Four 3D Facial Scanning Technologies: From Photogrammetry to Structured-Light Systems in Clinical Dentistry

Oana Elena Burlacu Vatamanu, Sergiu Drafta, Vanda Roxana Nimigean, Corina Marilena Cristache
Dentistry Journal
Orthodontics and Dentofacial Orthopedics
article

Evaluation of Four 3D Facial Scanning Technologies: From Photogrammetry to Structured-Light Systems in Clinical Dentistry

Oana Elena Burlacu Vatamanu, Sergiu Drafta, Vanda Roxana Nimigean, Corina Marilena Cristache
article en

Abstract

<b>Background/Objectives:</b> Accurate three-dimensional (3D) facial scanning is increasingly important in digital dentistry for diagnosis, treatment planning, and virtual patient creation. Multiple facial scanning technologies are available; however, their metric reliability varies depending on acquisition principles and anatomical orientation. This study aimed to evaluate the trueness, orientation-dependent performance (vertical midline versus horizontal facial measurements), and scanning time of four facial scanning technologies using calibrated manual anthropometry as the reference standard. <b>Methods:</b> Thirty dentate adult participants received adhesive fiducial markers on five predefined facial landmarks. Four linear facial distances were measured clinically using a digital caliper and compared with corresponding measurements obtained from standardized 3D facial scans. Digital measurements were extracted following uniform metric normalization. Inter-examiner reliability, measurement trueness, orientation-related differences, and scanning time were analyzed. <b>Results:</b> Inter-examiner reliability was excellent for both clinical and digital measurements (ICC > 0.93). All facial scanning technologies significantly overestimated manual distances (<i>p</i> < 0.001). The structured-light scanning system showed the smallest deviations (typically <1 mm) and the highest overall accuracy, followed by the depth-fusion system, while photogrammetry-based and NeRF-based approaches demonstrated larger errors, frequently exceeding 2-3 mm. Horizontal facial distances consistently showed greater deviations than vertical midline measurements across all systems. Scanning time differed significantly between technologies, with passive image-based approaches being the fastest and NeRF-based acquisition requiring the longest capture time. <b>Conclusions:</b> Active structured-light facial scanning demonstrated the highest trueness for linear facial anthropometry, whereas passive photogrammetry and NeRF-based approaches showed lower metric trueness and are currently more suitable for educational applications.

Dentistry JournalVol. 14(2)
Carol Davila University of Medicine and Pharmacy (RO)
Quality Education
Openalex Percentile: Top 55%
Orthodontics and Dentofacial Orthopedics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.