Management of Implantable Cardiovascular Devices in Patients Undergoing Radiotherapy

The increasing coexistence of oncological disease and cardiovascular implantable technology poses complex clinical challenges that require close collaboration among cardiologists, electrophysiologists, radiation oncologists, and medical physicists. A structured, systematic, and multidisciplinary approach is essential for the safe management of cancer patients with a cardiac implantable electronic device (CIED) undergoing radiation therapy. This document reports a consensus statement issued by the Italian Association of Hospital Cardiologists (ANMCO), aiming to provide practical guidance for clinicians involved across the entire care continuum of this high-risk patient population. A comprehensive pre-treatment evaluation is strongly recommended, including detailed assessment of the type of radiotherapy, treatment planning parameters, device characteristics, and patient-specific cardiac conditions, to minimize the risk of CIED malfunction. Particular emphasis is placed on risk stratification before radiation therapy, as well as on the appropriate timing and modality of cardiological assessments during treatment and in the post-therapy follow-up phase. The document offers an overview of oncological electrophysiology and the mechanisms of radiation-induced damage to cardiac devices with the goal of supporting standardized, safe, and effective clinical practice in this evolving field.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-02-14
DOI
https://doi.org/10.3390/diagnostics16040578
Primary Topic
Chemotherapy-induced cardiotoxicity and mitigation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Management of Implantable Cardiovascular Devices in Patients Undergoing Radiotherapy

Rossella Troccoli, Simona Giubilato, Carlo Pignalberi, C Bilato et al.
Diagnostics
Chemotherapy-induced cardiotoxicity and mitigation
article

Management of Implantable Cardiovascular Devices in Patients Undergoing Radiotherapy

Rossella Troccoli, Simona Giubilato, Carlo Pignalberi, C Bilato, Martina Nesti, Fabio Turazza, Maria Laura Canale, Furio Colivicchi, Irma Bisceglia, Fabrizio Oliva, Massimo Grimaldi, Stefano Oliva, Antonio Di Monaco
article en

Abstract

The increasing coexistence of oncological disease and cardiovascular implantable technology poses complex clinical challenges that require close collaboration among cardiologists, electrophysiologists, radiation oncologists, and medical physicists. A structured, systematic, and multidisciplinary approach is essential for the safe management of cancer patients with a cardiac implantable electronic device (CIED) undergoing radiation therapy. This document reports a consensus statement issued by the Italian Association of Hospital Cardiologists (ANMCO), aiming to provide practical guidance for clinicians involved across the entire care continuum of this high-risk patient population. A comprehensive pre-treatment evaluation is strongly recommended, including detailed assessment of the type of radiotherapy, treatment planning parameters, device characteristics, and patient-specific cardiac conditions, to minimize the risk of CIED malfunction. Particular emphasis is placed on risk stratification before radiation therapy, as well as on the appropriate timing and modality of cardiological assessments during treatment and in the post-therapy follow-up phase. The document offers an overview of oncological electrophysiology and the mechanisms of radiation-induced damage to cardiac devices with the goal of supporting standardized, safe, and effective clinical practice in this evolving field.

DiagnosticsVol. 16(4)
Azienda Universitaria Ospedaliera Consorziale - Policlinico Bari (IT), Azienda Ospedaliera San Camillo-Forlanini (IT), Associazione Nazionale Medici Cardiologi Ospedalieri (IT), AULSS 2 Marca Trevigiana (IT), Health Care Foundation (CA), Presidio Ospedaliero (IT), Istituto Tumori Bari (IT), Ospedale Cannizzaro (IT), Ospedale Generale Regionale Francesco Miulli (IT), Ospedale Versilia (IT), Fondazione Toscana Gabriele Monasterio (IT), Oldham Council (GB)
Openalex Percentile: Top 58%
Chemotherapy-induced cardiotoxicity and mitigation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.