On the accuracy of image registration in portable low-field 3D brain MRI

Portable low-field MRI offers an affordable and mobile alternative to conventional high-field scanners, enabling imaging in point-of-care and resource-limited settings. However, its lower signal-to-noise ratio, reduced resolution, and acquisition artifacts raise concerns about the accuracy of standard image registration methods. Reliable registration is critical for a wide range of emerging applications, including frequent brain monitoring, assessment of neurodegenerative disease progression, and evaluation of treatment effects such as those of Alzheimer's therapeutics. In this work, we systematically evaluated state-of-the-art registration approaches on simulated low-field scans (obtained by downsampling high-field images) and on real low-field brain MRI data. We compared three representative approaches: classical optimization (NiftyReg), learning-based registration (SynthMorph), and synthesis-based registration (SynthSR+NiftyReg). Using downsampled high-field scans, all methods performed well, achieving high Dice scores and smooth deformation fields, indicating that reduced resolution alone does not hinder registration. In contrast, real low-field data exhibited lower accuracy, primarily due to geometric distortion and other acquisition-specific artifacts. Among the tested approaches, the synthesis-based pipeline achieved the most robust performance across subjects and modalities. Overall, existing algorithms can accommodate resolution limitations, however, future methods could further enhance coregistration by explicitly addressing the distortions present in low-field MRI scans.

Authors

Institutions

Publication Details

Journal
bioRxiv (Cold Spring Harbor Laboratory)
Published
2026-02-14
DOI
https://doi.org/10.64898/2026.02.11.705413
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On the accuracy of image registration in portable low-field 3D brain MRI

Matthew Rosen, Mark Olchanyi, Karthik Gopinath, Ava Farnan et al.
bioRxiv (Cold Spring Harbor Laboratory)
Advanced MRI Techniques and Applications
article

On the accuracy of image registration in portable low-field 3D brain MRI

Matthew Rosen, Mark Olchanyi, Karthik Gopinath, Ava Farnan, Amelia Demopoulos, Ian Johnson, Dina Zemlyanker, Lin Tian, W. Taylor Kimberly, Jonathan Williams-Ramirez, Kevin N Sheth, Adam de Havenon, Annabel Sorby-Adams, Juan Eugenio Iglesias, Alzheimer’s Disease Neuroimaging Initiative (ADNI)
article en

Abstract

Portable low-field MRI offers an affordable and mobile alternative to conventional high-field scanners, enabling imaging in point-of-care and resource-limited settings. However, its lower signal-to-noise ratio, reduced resolution, and acquisition artifacts raise concerns about the accuracy of standard image registration methods. Reliable registration is critical for a wide range of emerging applications, including frequent brain monitoring, assessment of neurodegenerative disease progression, and evaluation of treatment effects such as those of Alzheimer's therapeutics. In this work, we systematically evaluated state-of-the-art registration approaches on simulated low-field scans (obtained by downsampling high-field images) and on real low-field brain MRI data. We compared three representative approaches: classical optimization (NiftyReg), learning-based registration (SynthMorph), and synthesis-based registration (SynthSR+NiftyReg). Using downsampled high-field scans, all methods performed well, achieving high Dice scores and smooth deformation fields, indicating that reduced resolution alone does not hinder registration. In contrast, real low-field data exhibited lower accuracy, primarily due to geometric distortion and other acquisition-specific artifacts. Among the tested approaches, the synthesis-based pipeline achieved the most robust performance across subjects and modalities. Overall, existing algorithms can accommodate resolution limitations, however, future methods could further enhance coregistration by explicitly addressing the distortions present in low-field MRI scans.

bioRxiv (Cold Spring Harbor Laboratory)
Yale University (US), Massachusetts General Hospital (US), Center for Neuro-Oncology (US), Athinoula A. Martinos Center for Biomedical Imaging (US), Center for Systems Biology (US), Massachusetts Institute of Technology (US)
U.S. Department of Defense, Alzheimer's Association, Bristol-Myers Squibb, Eli Lilly and Company, Pfizer, Biogen, University of Southern California, Meso Scale Diagnostics, Alzheimer's Disease Neuroimaging Initiative, BioClinica, Novartis Pharmaceuticals Corporation, Northern California Institute for Research and Education, Eisai, Servier, H. Lundbeck A/S, IXICO, National Institutes of Health, Genentech, Canadian Institutes of Health Research
Openalex Percentile: Top 55%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.