Effects of extended storage of blood samples on the results of platelet function testing: an <i>in vitro</i> stability study

In the present study, we aimed to explore the effects of extended storage of blood samples from 30 patients on the results of platelet function testing using the PFA-200 device (Collagen/EPI and Collagen/ADP tests), Multiplate instrument (ASPI, ADP, and TRAP tests), and VerifyNow analyzer (Aspirin and PRU tests). We determined platelet function (1) immediately after blood collection (baseline), (2) after storage of blood samples at room temperature for 3-4 h (i.e. the maximum sample storage period permitted by the manufacturers), and (3) after storage of blood samples for 5 h at room temperature (extended storage). Per the concept of acceptable change limits, platelet function was considered stable in time course if the median relative deviation from baseline values at a given time was <19% or <28%, depending on the test used. By applying our analyte stability limits, we found that blood samples could be stored for up to 5 h when performing the Collagen/ADP, ASPI, ADP, TRAP, Aspirin, and PRU tests. However, we observed significant deviations in the Collagen/EPI test results over time. The PFA-200 Collagen/EPI test results showed a median percentage deviation of 35% after 5 h of storage. However, no significant differences were observed between the measurements taken after 4 and 5 h of storage. We assume, that the baseline values of the Collagen/EPI test are measured incorrectly (presumably owing to malfunction of the test cartridges) and the following results are measured correctly.

Authors

Institutions

Publication Details

Journal
Scandinavian Journal of Clinical and Laboratory Investigation
Published
2026-02-14
DOI
https://doi.org/10.1080/00365513.2026.2630329
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of extended storage of blood samples on the results of platelet function testing: an in vitro stability study

Ulrich J. Sachs, Nenad Mitrovic, Thomas Mueller, Artur Hausch et al.
Scandinavian Journal of Clinical and Laboratory Investigation
Clinical Laboratory Practices and Quality Control
article

Effects of extended storage of blood samples on the results of platelet function testing: an in vitro stability study

Ulrich J. Sachs, Nenad Mitrovic, Thomas Mueller, Artur Hausch, Maria Deisenhammer
article en

Abstract

In the present study, we aimed to explore the effects of extended storage of blood samples from 30 patients on the results of platelet function testing using the PFA-200 device (Collagen/EPI and Collagen/ADP tests), Multiplate instrument (ASPI, ADP, and TRAP tests), and VerifyNow analyzer (Aspirin and PRU tests). We determined platelet function (1) immediately after blood collection (baseline), (2) after storage of blood samples at room temperature for 3-4 h (i.e. the maximum sample storage period permitted by the manufacturers), and (3) after storage of blood samples for 5 h at room temperature (extended storage). Per the concept of acceptable change limits, platelet function was considered stable in time course if the median relative deviation from baseline values at a given time was <19% or <28%, depending on the test used. By applying our analyte stability limits, we found that blood samples could be stored for up to 5 h when performing the Collagen/ADP, ASPI, ADP, TRAP, Aspirin, and PRU tests. However, we observed significant deviations in the Collagen/EPI test results over time. The PFA-200 Collagen/EPI test results showed a median percentage deviation of 35% after 5 h of storage. However, no significant differences were observed between the measurements taken after 4 and 5 h of storage. We assume, that the baseline values of the Collagen/EPI test are measured incorrectly (presumably owing to malfunction of the test cartridges) and the following results are measured correctly.

Scandinavian Journal of Clinical and Laboratory InvestigationVol. 86(2)
Thorlabs (Germany) (DE), Universitätsklinikum Gießen und Marburg (DE)
Openalex Percentile: Top 54%
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.