Poster Session I - A54 HUMAN-MACHINE INTERACTION IN OPTICAL POLYP DIAGNOSIS: DECISION-MAKING AFTER CADX POLYP DIAGNOSIS

Abstract Background Computer-assisted diagnosis (CADx) systems employ artificial intelligence algorithms to generate probabilistic outputs, assisting in polyp characterization. The clinical utility of these AI-generated predictions ultimately depends on the endoscopist’s ability to interpret and appropriately act upon them. CADx demands expertise from endoscopists, who must employ knowledge of polyp histology based on surface features and clinical judgement to accept or reject the AI-based polyp classifications. This requires a higher level of endoscopist knowledge to discern whether an AI-generated classification is accurate and should be incorporated into the final diagnosis or whether it requires correction. Aims Our study aimed to evaluate endoscopists’ decision-making when interpreting CADx predictions for each polyp category, compared to histopathology diagnosis as ground truth. Specifically, we examined the accuracy of accepted and rejected CADx outputs, the frequency and direction of overrides, and the patterns of reclassification following rejection. Methods We conducted a secondary analysis of a prospective cohort between 2022-2025 (NCT06822816) in which CADx was used during colonoscopies to classify polyps in real-time as either neoplastic or hyperplastic. Endoscopists could either accept the diagnosis made by CADx or reject it by providing an alternate prediction. They could chose to predict polyp histology as adenoma, hyperplastic or sessile serrated lesion. This histology prediction was made prior to resection and independent of pathology. All small (<10mm) polyps with documented CADx output, endoscopist histology prediction, and adenoma, hyperplastic or SSL pathology diagnosis were included. Results Our cohort included 754 polyps from 367 patients. Accepted CADx diagnoses were correct for 89.1% of neoplastic and 68.7% of hyperplastic CADx predictions. Endoscopists accepted incorrect classifications more frequently for hyperplastic than neoplastic polyps (31.3% vs.10.9%). Upon rejecting correct CADx neoplastic predictions, endoscopists misclassified 23.4% as sessile serrated lesions. Similarly, 29.5% of rejected correct CADx hyperplastic predictions were incorrectly reassigned as SSLs. Conclusions Endoscopists demonstrate a pronounced diagnostic bias towards neoplastic lesions, frequently misclassifying hyperplastic polyps as SSLs. While clinically safe, this phenomenon might have implications increasing downstream endoscopy procedures and cost-effectiveness of CADx, highlighting the necessity of incorporating comprehensive cost analyses including downstream colonoscopy utilization. Developing CADx systems with robust SSL identification capabilities will likely be critical in overcoming these diagnostic challenges and achieving effective integration into routine clinical practice. Funding Agencies None

Authors

Institutions

Publication Details

Journal
Journal of the Canadian Association of Gastroenterology
Published
2026-02-01
DOI
https://doi.org/10.1093/jcag/gwaf042.054
Primary Topic
Colorectal Cancer Screening and Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Poster Session I - A54 HUMAN-MACHINE INTERACTION IN OPTICAL POLYP DIAGNOSIS: DECISION-MAKING AFTER CADX POLYP DIAGNOSIS

Roupen Djinbachian, D Dubois, Victoire Michal, Megan Oleksiw et al.
Journal of the Canadian Association of Gastroenterology
Colorectal Cancer Screening and Detection
article

Poster Session I - A54 HUMAN-MACHINE INTERACTION IN OPTICAL POLYP DIAGNOSIS: DECISION-MAKING AFTER CADX POLYP DIAGNOSIS

Roupen Djinbachian, D Dubois, Victoire Michal, Megan Oleksiw, Heiko Pohl, Y Jalal, D Von Renteln, C Hassan, D K Rex
article en

Abstract

Abstract Background Computer-assisted diagnosis (CADx) systems employ artificial intelligence algorithms to generate probabilistic outputs, assisting in polyp characterization. The clinical utility of these AI-generated predictions ultimately depends on the endoscopist’s ability to interpret and appropriately act upon them. CADx demands expertise from endoscopists, who must employ knowledge of polyp histology based on surface features and clinical judgement to accept or reject the AI-based polyp classifications. This requires a higher level of endoscopist knowledge to discern whether an AI-generated classification is accurate and should be incorporated into the final diagnosis or whether it requires correction. Aims Our study aimed to evaluate endoscopists’ decision-making when interpreting CADx predictions for each polyp category, compared to histopathology diagnosis as ground truth. Specifically, we examined the accuracy of accepted and rejected CADx outputs, the frequency and direction of overrides, and the patterns of reclassification following rejection. Methods We conducted a secondary analysis of a prospective cohort between 2022-2025 (NCT06822816) in which CADx was used during colonoscopies to classify polyps in real-time as either neoplastic or hyperplastic. Endoscopists could either accept the diagnosis made by CADx or reject it by providing an alternate prediction. They could chose to predict polyp histology as adenoma, hyperplastic or sessile serrated lesion. This histology prediction was made prior to resection and independent of pathology. All small (<10mm) polyps with documented CADx output, endoscopist histology prediction, and adenoma, hyperplastic or SSL pathology diagnosis were included. Results Our cohort included 754 polyps from 367 patients. Accepted CADx diagnoses were correct for 89.1% of neoplastic and 68.7% of hyperplastic CADx predictions. Endoscopists accepted incorrect classifications more frequently for hyperplastic than neoplastic polyps (31.3% vs.10.9%). Upon rejecting correct CADx neoplastic predictions, endoscopists misclassified 23.4% as sessile serrated lesions. Similarly, 29.5% of rejected correct CADx hyperplastic predictions were incorrectly reassigned as SSLs. Conclusions Endoscopists demonstrate a pronounced diagnostic bias towards neoplastic lesions, frequently misclassifying hyperplastic polyps as SSLs. While clinically safe, this phenomenon might have implications increasing downstream endoscopy procedures and cost-effectiveness of CADx, highlighting the necessity of incorporating comprehensive cost analyses including downstream colonoscopy utilization. Developing CADx systems with robust SSL identification capabilities will likely be critical in overcoming these diagnostic challenges and achieving effective integration into routine clinical practice. Funding Agencies None

Journal of the Canadian Association of GastroenterologyVol. 9(Supplement_1)
White River Junction VA Medical Center (US), Centre Hospitalier de l’Université de Montréal (CA), IRCCS Humanitas Research Hospital (IT), Indiana University School of Medicine, Indiana University – Purdue University Indianapolis (US)
Peace, Justice and strong institutions
Openalex Percentile: Top 56%
Colorectal Cancer Screening and Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.