Noise-robust method using sparsity for locating a crack in a steel rod based on the Fourier coefficients of the leakage magnetic flux
In the leakage magnetic flux (LMF) method for non-destructive inspection, locating a tiny crack with a depth of less than 100 µm is a challenge due to the low signal-to-noise ratio. This paper presents a noise-robust method for locating a tiny surface crack in a moving steel rod. For the time series data obtained with our two previously proposed sensors, which measure the circumferential Fourier cosine and sine coefficients of the LMF, we introduce a method that solves a linear inverse problem with sparsity regularization, enabling localization of a crack with a depth of 70 µm.
Authors
- Youhei Kuwahara
- Kanta Shiku (ORCID: https://orcid.org/0009-0004-8154-5439)
- Yuji Gotoh (ORCID: https://orcid.org/0000-0001-5977-9520)
- Takaaki Nara (ORCID: https://orcid.org/0000-0002-9955-4542)
- N. Shigematsu
Institutions
- Tokyo University of Science (JP)
- Oita University (JP)
- Kanagawa University (JP)
- The University of Tokyo (JP)
Publication Details
- Journal
- AIP Advances
- Published
- 2026-02-01
- DOI
- https://doi.org/10.1063/9.0001008
- Primary Topic
- Non-Destructive Testing Techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.00