Application Research of Fire-Extinguishing Polymer Composite (FEPC) in Mobile Power Outlets

With the increasing popularity of electrical equipment and power demand, mobile power outlets are widely used in daily life and industrial settings. However, due to their compact structure and limited heat dissipation conditions, mobile power outlets often catch fire due to overload or short circuits. This paper analyzes the ignition situation of sample power outlets under different overload powers and identifies two key points of ignition during the overload process based on the combustion triangle: combustible smoke (flammable gases, flammable vapors, and organic macromolecular particles) and high-temperature electric arcs. The effect of the number and position of fire-extinguishing polymer composite (FEPC) on sample power outlets during the overload process is tested. The experimental results show that when more than three 3 cm<sup>2</sup> pieces of FEPC are attached inside the power strip, the concentration of C<sub>6</sub>F<sub>12</sub>O released by the FEPC upon heating can reach the effective fire-extinguishing concentration. This effectively inhibits the ignition of plastic and its thermally decomposed combustible fumes by high-temperature electric arcs. When the FEPC is attached to the exterior of the power strip, the C<sub>6</sub>F<sub>12</sub>O released by the FEPC upon heating diffuses into the external environment. This results in the C<sub>6</sub>F<sub>12</sub>O concentration inside and around the power strip being significantly lower than the effective fire-extinguishing concentration, thereby rendering it ineffective in preventing fires. By investigating the influence of the number and placement of FEPC on power strips during overload conditions, this study aims to provide new insights into fire prevention in electrical outlets.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2026-02-12
DOI
https://doi.org/10.1021/acsomega.5c13310
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application Research of Fire-Extinguishing Polymer Composite (FEPC) in Mobile Power Outlets

Jin Tian, Hao Liu, Lingrui Kong, Tianwei Zhang et al.
ACS Omega
Fire dynamics and safety research
article

Application Research of Fire-Extinguishing Polymer Composite (FEPC) in Mobile Power Outlets

Jin Tian, Hao Liu, Lingrui Kong, Tianwei Zhang, Gengyi Su
article en

Abstract

With the increasing popularity of electrical equipment and power demand, mobile power outlets are widely used in daily life and industrial settings. However, due to their compact structure and limited heat dissipation conditions, mobile power outlets often catch fire due to overload or short circuits. This paper analyzes the ignition situation of sample power outlets under different overload powers and identifies two key points of ignition during the overload process based on the combustion triangle: combustible smoke (flammable gases, flammable vapors, and organic macromolecular particles) and high-temperature electric arcs. The effect of the number and position of fire-extinguishing polymer composite (FEPC) on sample power outlets during the overload process is tested. The experimental results show that when more than three 3 cm<sup>2</sup> pieces of FEPC are attached inside the power strip, the concentration of C<sub>6</sub>F<sub>12</sub>O released by the FEPC upon heating can reach the effective fire-extinguishing concentration. This effectively inhibits the ignition of plastic and its thermally decomposed combustible fumes by high-temperature electric arcs. When the FEPC is attached to the exterior of the power strip, the C<sub>6</sub>F<sub>12</sub>O released by the FEPC upon heating diffuses into the external environment. This results in the C<sub>6</sub>F<sub>12</sub>O concentration inside and around the power strip being significantly lower than the effective fire-extinguishing concentration, thereby rendering it ineffective in preventing fires. By investigating the influence of the number and placement of FEPC on power strips during overload conditions, this study aims to provide new insights into fire prevention in electrical outlets.

ACS OmegaVol. 11(7)
New York City Fire Department (US), Hebei University of Technology (CN)
Openalex Percentile: Top 64%
Fire dynamics and safety research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Application Research of Fire-Extinguishing Polymer Composite (FEPC) in Mobile Power Outlets — Jin Tian, Hao Liu, et al. · ACS Omega (2026) | TGRS Research Map | TGRS